19
■
Installation
Location (cont.)
On the verge of trouble caused by static voltage is the best place of installation.
Object material should be floated (no touch with the other materials).
Effectiveness will be lost if there is something on the back side of the object materials.
Electrode needle should be point to object materials.
Electrode needle should be away more than 15mm from object materials and close less than
50mm (with no air assist).
Lesser distance between electrode needle and object materials better performance. For higher
static voltage or faster moving of object materials, closer distance will be better for result.
There should be no materials between electrode needles and object materials.
Never cut / vend electrode. Always consider additional space for install.
Do not forget about space for H.V. cable expands from the side of electrode bar.
Ionizer does not coat object materials. So, the object materials will be charged even after static
elimination.
Eliminate the static voltage from both side of object materials is 0.1mm or more thickness. 2 or
more bars of horizontal array installation may bring better results for very high-speed moving
materials.
Examples
Installation
Caution
REMEMBER
Installation and maintenance should be conducted by a person proficient
in electric works including wiring.
Never drill or add the other modify to the product.
This product should be fixed. Do not put into use with moving.
PROHIBITED
Do not cover electrode needles by brackets or the other materials.
Materials within 15mm from electrode needle will cause spark or lightning
voltage escalating to faults of product.
Do not touch objects to electrode. Be sure there is no hit by moving arms,
heads or the other machine parts.
Do not twist or vend the electrode. Extreme residual stress may cause
break of casing and dropping of electrode needles or pitch block as a
result of that.
Not good location
(materials on the back of object)
Objects
Films / Sheets
Good location
Good location
Good location