 Installation 

Connecting the High Voltage Cable 

The high voltage shield cable is a special electric wire. It is a high-voltage resistance silicone cable which is coated 

with a shield and polyurethane connecting to the ground portion. Connect the cable in the following procedure: 

 

1.  Determine the wiring route of the high voltage cable from the air gun HPG-1 to High Voltage Power Supply 

GP-1. 

* In the wiring route, do not include places, such as a passage, in which a heavy object passes over the cable. 

 

2.  Connect the high voltage cable 

with High Voltage Power Supply 

GP-1. Connect the high voltage 

connector of the high voltage 

cable terminal to the output 

connector of the GP-1. You can 

connect the high voltage 

connector just by inserting and 

screwing it into the output 

connector by hands. Being made of 

resin, the connection portion may 

be damaged if a tool such as a plier 

is used. Be sure to connect it by 

hands. 

 

3. Connect the ground wire of the high voltage shield cable terminal to the ground terminal of the GP-1. 

 

4. Fix the high voltage cable on the top cover of the GP-1, using the provided nylon clips. This can prevent pulling 

tension and others from being applied to the high voltage connector portion. 

 

5. 

Twist an accompanying sticker around the high voltage 

cable at an arbitrary place. It is recommended to attach it at 

the place where it is well remarked by the operator.

 

 

Connecting the Air Tube 

1.  Connect an air tube (outside diameter of 8 mm and inside diameter of 5 mm) to the one-touch joint which is 

located on the bottom of the grip portion of the gun body. The one-touch joint can be replaced with the coupler 

joint (standard accessory). When supplying air from the top of the product, replace the end plug on the upper 

section with the one-touch joint on the bottom section of the gun body. Before connecting, tightly wrap each 

screw portion with a sealing tape. 

 

2. Supply clean and dry air to the gun. If necessary, use an air filter or a mist separator. The cleanliness of air has a 

great influence on the frequency of cleaning of the electrode and the product lifetime. 

 

 Operation 

Operation Procedure 

Supply clean and dry air to the gun, and turn the power switch of High Voltage Power Supply GP-1 on. 

When you pull the trigger of the gun, ionized compressed air is brown off to eliminate static charges and dusts. 

Turn the power switch of the GP-1 off when you don’t use the gun. 

* Even if the trigger is not pulled, high voltage is being supplied to the gun when the power switch of the GP-1 is on. 
* When high pressure air is used, the operator and other people working around him/her must wear a protector such as 

earplugs. Being exposed to high-tone noise for a long time may cause hearing loss or another disability. 

Summary of Contents for HPG-1

Page 1: ... charges 〇 It is intended to be used to address various production problems caused by electrostatic charges CONTENTS Before Using the Product P 2 Product Overview P 3 Main Specifications P 4 External Dimension P 5 Installation P 6 Operation Procedure P 8 Maintenance and Anomaly Handling P 9 Troubleshooting P 10 Storage P 10 ...

Page 2: ...lorine and so on There is a risk of electric shock and or product breakdown PROHIBITED Don t use this product in a place where a considerable shock and or vibration are given and or where a sharp temperature fluctuation or dew condensation occurs PROHIBITED Be sure to use this product within a range of conditions of use in the section of Specifications including the electric rating Otherwise there...

Page 3: ...roduct This cable is also shielded so it reduces the negative influences by the high voltage electric field in consideration of EMC and simplifies the wiring Urethane cleaning easy material is used for cable exterior The cable length can be changed to up to 5m as an option Non shielded type is also available as option Please contact us for more detail Strong die cast aluminum gun body The gun body...

Page 4: ...time Approx 0 5 sec Input air pressure 0 3 MPa Distance 150 mm Ion balance Adjustable on the GP 1 4kV A charged plate monitor or equivalent is required Installation place Indoors Protection circuit High Voltage Power Supply GP 1 is equipped with a high voltage anomaly detection function and automatic stop circuit High voltage cable Standard accessory 3m cable 2 silicone shielded cable Termination ...

Page 5: ...5 External Dimension High Power Ionizing Gun HPG 1 ...

Page 6: ...upply GP 1 close to the equipment on which the air gun HPG 1 is installed Firmly secure it to a strong frame wall floor etc using four M5 screws through the holes in the bottom of the mounting base When installing the GP 1 on a vertical surface make sure the high voltage output connector is on the bottom The GP 1 weighs approximately 4 5 kg Please handle with great care to avoid serious injury due...

Page 7: ...power supply side to the ground terminal of high voltage power supply GP 1 Otherwise you may get an electric shock from the gun body or the high voltage cable REMEMBER If the high voltage cable is broken during power distribution sparks are emitted from it In that case immediately stop using it and ask repair Meanwhile if a short circuit occurs between the core wire and the shield coating groundin...

Page 8: ...ltage cable at an arbitrary place It is recommended to attach it at the place where it is well remarked by the operator Connecting the Air Tube 1 Connect an air tube outside diameter of 8 mm and inside diameter of 5 mm to the one touch joint which is located on the bottom of the grip portion of the gun body The one touch joint can be replaced with the coupler joint standard accessory When supplyin...

Page 9: ...op the supply of power to the body part and contact the dealer from which the product was purchased Other Anomalies If any of the following phenomena occur immediately stop the supply of power to the body part and contact the dealer from which the product was purchased Sparks are being emitted due to damage to the antistatic electrode or the high voltage cable The high voltage connector portion or...

Page 10: ...s to be connected to the GP 1 or replacing with the optional short high voltage cable The electrode and insulation of the gun body are extremely dirty Clean or replace the electrode etc Failure of the gun body or the high voltage cable short circuit etc If the GP 1 stops detecting anomaly when the high voltage cable is disconnected replace the electrode and the high voltage cable Breakdown of the ...

Page 11: ...11 memo ...

Page 12: ...s neglect misuse alterations operator error or failure to properly maintain clean or repair products LIMIT OF LIABILITY This electronic static eraser use high voltage corona discharge and should not be used in or near flammable or explosive environments In no event will VESSEL or any seller is responsible or liable for any injury loss or damage direct or consequential whether based in tort or cont...

Reviews: