8
■
Installation
Connecting the High Voltage Cable
The high voltage shield cable is a special electric wire. It is a high-voltage resistance silicone cable which is coated
with a shield and polyurethane connecting to the ground portion. Connect the cable in the following procedure:
1. Determine the wiring route of the high voltage cable from the air gun HPG-1 to High Voltage Power Supply
GP-1.
* In the wiring route, do not include places, such as a passage, in which a heavy object passes over the cable.
2. Connect the high voltage cable
with High Voltage Power Supply
GP-1. Connect the high voltage
connector of the high voltage
cable terminal to the output
connector of the GP-1. You can
connect the high voltage
connector just by inserting and
screwing it into the output
connector by hands. Being made of
resin, the connection portion may
be damaged if a tool such as a plier
is used. Be sure to connect it by
hands.
3. Connect the ground wire of the high voltage shield cable terminal to the ground terminal of the GP-1.
4. Fix the high voltage cable on the top cover of the GP-1, using the provided nylon clips. This can prevent pulling
tension and others from being applied to the high voltage connector portion.
5.
Twist an accompanying sticker around the high voltage
cable at an arbitrary place. It is recommended to attach it at
the place where it is well remarked by the operator.
Connecting the Air Tube
1. Connect an air tube (outside diameter of 8 mm and inside diameter of 5 mm) to the one-touch joint which is
located on the bottom of the grip portion of the gun body. The one-touch joint can be replaced with the coupler
joint (standard accessory). When supplying air from the top of the product, replace the end plug on the upper
section with the one-touch joint on the bottom section of the gun body. Before connecting, tightly wrap each
screw portion with a sealing tape.
2. Supply clean and dry air to the gun. If necessary, use an air filter or a mist separator. The cleanliness of air has a
great influence on the frequency of cleaning of the electrode and the product lifetime.
■
Operation
Operation Procedure
Supply clean and dry air to the gun, and turn the power switch of High Voltage Power Supply GP-1 on.
When you pull the trigger of the gun, ionized compressed air is brown off to eliminate static charges and dusts.
Turn the power switch of the GP-1 off when you don’t use the gun.
* Even if the trigger is not pulled, high voltage is being supplied to the gun when the power switch of the GP-1 is on.
* When high pressure air is used, the operator and other people working around him/her must wear a protector such as
earplugs. Being exposed to high-tone noise for a long time may cause hearing loss or another disability.
Summary of Contents for HPG-1