9
■
Maintenance and Anomaly Handling
Cleaning the Discharge Needle and the Gun
For quick cleaning, use a nylon blush, a soft cloth, or a cotton-tipped stick.
Be sure to turn the power of High Voltage Power Supply GP-1 off, and clean the gun tip portion
ranging from the air outlet to the discharge needle. It is recommended to supply air at a quite low
pressure (0.05 MPa or so) at the time of cleaning.
•
If removing the gun-tip metal portion without turning OFF High Voltage Power Supply GP-1, you get
an electric shock. Be sure to confirm the power is off. Also, do not remove the discharge needle.
•
Never use organic solvents, detergents, etc.
•
Pay enough attention to handle the discharge needle because its head is sharpened and tends to
easily prick skin. Also, if the discharge needle is bent or broken, be sure to replace it.
Contact us for repair and after-purchase service.
Sparks from the Discharge Needle
There should be no visible sparks from the static elimination device system during normal use. If you
see these kinds of sparks continuing to occur at the discharge needle, etc., make sure to perform
necessary maintenance such as cleaning the connected needle electrode. If cleaning cannot
eliminate the occurrence of sparks, stop the supply of power to the body part and contact the dealer
from which the product was purchased.
Other Anomalies
If any of the following phenomena occur, immediately stop the supply of power to the body part and
contact the dealer from which the product was purchased.
•
Sparks are being emitted due to damage to the antistatic electrode or the high voltage cable.
•
The high voltage connector portion or a part of the high voltage cable has melted. It is smoking
or burning.
•
A strange smell is coming from the body part. Or, it is making an unusual humming sound.
(which can be heard from 1 m away)
•
The body part is considerably distorted. Or, it is abnormally hot. (enough that it cannot be
touched with bare hands)
Caution
PROHIBITED
Do not use the product in the following conditions. Risk of fire or electric shock.
•
The product is broken due to dropping or shock.
•
The power indicator light does not come on even though the power switch
is turned to ON.
•
The cord is damaged or heated up.
•
The plug to the connector or outlet is loose.
Power off
When any abnormal condition is detected, turn off the power switch and pull
out the power supply connector.
Prohibition of
disassembly
Never disassemble the product.
Continuously using the product during failure or abnormal conditions may lead to product
breakdowns or accidents, so please request repairs in a timely manner. Contact the dealer from which
the product was purchased for repairs.