17
Installation
Compressed air piping
CAUTION
Remember
Be sure to use an air hose with sufficient pressure resistance
performance. A hose without pressure resistance could burst or leak air.
Compressed air used
This unit requires that clean compressed air be supplied to the dust removal air blower.
Supply air within the pressure range of 0.4 to 0.7 MPa.
*A pilot solenoid valve is used to assist the operation of the valve used to supply the compressed
air, and it will not operate properly if the supply pressure is too low.
Use an air drier to remove the moisture from the air. (The dew point temperature is -15°C or
lower.) Use mist separator (0.3
μ
m) to remove the impurities from the air.
Supply air within the temperature range of 0 to +40°C.
Hose used
Use an air hose with sufficient pressure resistance performance (outside diameter 6 mm x inside
diameter 4 mm).
Hose connection
Connect the hose to the one-touch hose coupling (compressed air supply opening) on the bottom of
the solenoid valve on the back of the work hood. Refer to the following figure.