34
Removal
Removal
When removing this product, first make sure the surrounding area and other workers are safe.
CAUTION
Unplug power cable
To prevent electrical shock accidents and operational mistake
accidents during the product removal work, be sure to unplug the
power cord from the outlet.
Remember
When disconnecting a compressed air hose, be sure to first shut off the
source of the compressed air. In addition, the compressed air inside
the air hose could spray out when the air hose is disconnected, so keep
the hose away from the face, etc., when disconnecting it.
Remember
To keep the unit from falling over, do not climb on the hood or dust
collector or place heavy objects on them.
Remember
Check the following, being aware of the weight of the product.
・
Be sufficiently careful that no part of the body, especially fingers and
toes, will be caught underneath the product while it is being removed
or moved.
・
Make sure the product does not fall over while it is being removed or
moved.
・
Do not move the product while an object is set on its hood. The
object could fall off of the hood.
Disposal
Disposal
When disposing of this product, dispose of it properly in accordance with the pertinent laws and
local regulations.
Replacement Parts
Replacement Parts
There are 3 consumable parts that can be replaced by the
customer.
Check the model and lot No. and then purchase the parts
through the store where the product was purchased.
○
Filter unit part No. (22)
○
Front clear acrylic sheet part No. (2)
○
Rear filter part No. (25)
For information about the replacement procedure, refer to the “ Maintenance” item in this manual.
Summary of Contents for IPC40-E
Page 9: ...9 Dimensions ...