29
■
Functions of parts
Power supply terminal specification
No,
Inter Electric
Wire Color
Functions
Attached Cable
1
Brown
24VDC
±
5%
min. 1A
Power supply cable
2
Brown/White
3
No connection
4
5
Green
Ground (0V)
6
Green/White
7
Blue
8
Blue/White
COMPULSORY
EARTH GROUNDING
A built-in high voltage power supply is adopted for AC PULSE ION BAR C-series and the
components that surround the power supply consist of low voltage circuit such as
microcomputers. Therefore, it is absolutely required to ground the earth connection to prevent the
electrical troubles, breakdown, or lead to adverse effect to functions and performance of the
product. Make sure to ground the unit as instructed below in order to prevent the secondary effect
to the external equipment as well.
Installation
Installation location
WARNING
PROHIBITED
Do not use the ion bar in the following environments:
• Where explosion-proofing is required.
• Where corrosive, inflammable, or explosive gas is handled.
CAUTIONS
REMEMBER
Consider the following when choosing the installation location:
• Install the ion bar in an indoor place where it is not subject to wind, rain, or direct
sunlight.
• Avoid installing the ion bar in a place where it may be wet by water or oil.
• Avoid installing the ion bar in a place where it is subject to strong vibration or shock.
• Install the ion bar in a place where the temperature is 0 - 50ºC and humidity is
35-85%.