32
■
Operation
Operation
WARNING
UNPLUG
Be sure to unplug the power supply cable before inspecting the ion bar
to avoid an electric shock.
CAUTIONS
DO NOT
DISASSEMBLE
Do not disassemble the ion bar. There are very dangerous
high-voltage components inside.
PROHIBITED
Do not block the air inlet or outlet and other openings.
Doing so may cause a failure.
PROHIBITED
Do not insert a metal or foreign substance into an opening.
Doing so may cause an electric shock or failure.
UNPLUG
Be sure to unplug the power supply cable when the ion bar is not used
for a long period. If it is left plugged for a long period, insulation may
get deteriorated to cause an electric shock, failure, or fire.
Setup
The setting can be changed using the operation panel buttons or supplied remote controller. Use a
measurement tool such as charge plate monitor to check the status while changing the setting.
Dip switch setting
H
.
V
. High voltage alarm setting
[Switch 1: On] When alarm occurs due to abnormal condition, H/V lamp
indicates and Al-1 is displayed.
[Switch 1: Off] When alarm occurs due to abnormal condition, the ion bar is
not working.
A/BAL Auto balance mode setting
[Switch 2: On] Auto balance function is activated
(Please use this function within 100mm between the object to C-bar.)
(It may take up to 10 seconds for this device to store the settings.)
[Switch 2: Off] It works as default pulse value.
Please refer to P.34.
TIP/C Tip cleaning timer setting
[Switch 3: On] Tip Cleaning Alarm function is activated (LED signal indicate
when the set-time is passed)
[Switch 3: OFF] Tip Cleaning Alarm function is not activated
※
Please set the time after Tip Cleaning Dip Switch “On”.