25
Troubleshooting
If the range hood or halogen light does not work after
installation
• Check if the range hood has been plugged in, make sure
that all power has been turned back ON, fused not blown
and all electrical wiring are properly connected.
• Swap out light assembly to working ones to determine
whether it is caused by defective bulbs. See
Replacing the
light bulbs
on Page 34-36.
The range hood vibrates when the blower is on
• The range hood might not have been secured properly on to
the ceiling or wall. Check with your installer
The blower or fan seems weak
• Check that the duct sized used is at least 6” or 3-1/4 × 10”.
Range hood WILL NOT function efficiently with insufficient duct
size. For example: 8” duct over 6” hole and loosely secured.
• Check if duct is clogged or if damper unit (half-circular
flapper) is not installed correctly or opening properly. A tight
mesh on a side wall cap unit might also cause restriction to
the air flow.
The lights work but the blower is not spinning at all, is stuck or
is rattling
The blower might be jammed or scraping the bottom due to
shipping damage. Please contact us immediately.