Venting Requirements
Vent system must terminate to the outside (roof or side wall).
DO NOT terminate the vent system in an attic or other enclosed
area.
DO NOT use 4”
(
10.2 cm) laundry-type wall caps
.
Use metal/aluminum vent only
.
Rigid
metal/aluminum vent is
recommended.
DO NOT use plastic vent.
Always keep the duct clean to ensure proper air ow
.
Calculate the following gures before installation:
1
.
Distance from the oor to the ceiling.
2
.
Distance between the oor to the countertop/stove (US
Standard:
36”).
3
.
Distance between the countertop/stove to the range hood
(
recommend* 28”
to 31”).
4
.
Height of hood and duct cover
.
For the most ef cient & quiet operation:
A distance of 28”
to 31”
is recommended* between stove top
and the bottom of range hood.
It is recommended that the range hood be vented vertically
through the roof through 6”
(
15.2 cm)
or bigger round metal/
aluminum vent work.