Troubleshooting
If the range hood or halogen light does not work after
installation
•
Check if the range hood has been plugged in,
make sure
that all power has been turned back ON,
fused not blown
and all electrical wiring are properly connected.
•
Swap out light assembly to working ones to determine
whether it is caused by defective bulbs
.
See Replacing the
light bulbs
on Page 32.
The range hood vibrates when the blower is on
•
The range hood might not have been secured properly on to
the ceiling or wall.
Check with your installer
The blower or fan seems weak
•
Check that the duct sized used is at least 6”
or 3-1/4 × 10
”.
Range hood WILL NOT function ef ciently with insuf cient duct
size
.
For example:
8
”
duct over 6”
hole and loosely secured.
•
Check if duct is clogged or if damper unit (half-circular
apper) is not installed correctly or opening properly
.
A tight
mesh on a side wall cap unit might also cause restriction to
the air ow
.
The lights work but the blower is not spinning at all, is stuck or
is rattling
The blower might be jammed or scraping the bottom due to
shipping damage
.