2
unable to be added into the current Z-Wave Gateway/Control Panel, please exclude it first (see
Removing
Device
) before attempting to
include
it into the current Z-Wave Gateway/Control Panel.
Removing Device (Exclusion)
The device must be removed from existing Z-Wave network before being included into another. There are two
methods available to exclude a device.
Exclusion Mode
Put the Z-Wave Gateway or Control Panel into
Exclusion mode
(please refer to the Z-Wave Gateway or Control
Panel manual).
Within 1.5 seconds, press the Function Button 3 times and the device will be removed from the Z-Wave network.
Factory Reset
(Only use factory reset when network Control Panel/Gateway is missing or inoperable).
Press and hold the Function Button of the device for 10 seconds to factory reset.
<NOTE>
Factory resetting the device will restore it to factory default settings (excluded from the Z-Wave network).
The Z-Wave Gateway or Control Panel will still keep its Z-Wave settings. Please refer to the Gateway or
Control Panel manual on how to remove the device’s Z-Wave settings.
Factory resetting the device will also clear all accumulated power data.
Range Test
To test whether the device is able to communicate with the Z-Wave Gateway or Control Panel:
Put the Gateway / Panel into range test mode (Walk Test).
Press the Function Button on the device.
The Gateway / Panel should display if the device is within the operation range (please refer to the operation
manual of the Gateway / Panel).
Z-Wave Router Device Capacity
The Power Switch allows other Z-Wave devices to join the Z-Wave Network through the Router. The maximum
capacity of the devices to join the Z-Wave Network through the Power Switch is 255.
Operation
Appliance Control
After being included into a Z-Wave Gateway or Control Panel, plug a home appliance into the Power Switch.
This home appliance’s power and energy usage data will be transferred to the Control Panel.
Users can remotely turn on/off the electric appliance through the Control Panel (please refer your Control Panel
manual).
Pressing the Function Button on the Power Switch can also toggle on/off the Power Switch.
The Power Switch transmits a signal with power data to Z-Wave Gateway/Panel every 10 minutes starting from
the last time a signal is transmitted.
When the Power Switch is re-plugged after it has been removed from the power outlet, the previous on/off status
of Power Switch will be resumed immediately.
Energy Consumption Monitor (PSM-29ZW only)
If the power output is below 1kW, PSM-29 will transmit a signal to Z-Wave Gateway/Panel when the power
deviates by +/- 2W to update PSM-29’s power information.
If the power output is above 1kW, PSM-29 will transmit a signal to Z-Wave Gateway/Panel when the power
deviates by +/- 5W to update PSM-29’s power information.
The Power Switch transmits a signal with power data to Z-Wave Gateway/Panel whenever power usage
increases by 0.1kW/hr.
When the power is below 20W, measurement error is more likely to occur.
Power Specification
For
110V:
the maximum operation load is 1760W and 16A. Warning: please do not exceed the maximum load.
For
230V:
the maximum operation load is 3680W and 16A. Warning: please do not exceed the maximum load.
If the Power Switch is overheating, it will cut off power automatically as a safety measure. The Power Switch
must be un-plugged and re-plugged after cut off to resume normal operation.