background image

 

unable to be added  into the current Z-Wave  Gateway/Control Panel, please exclude it first (see 

Removing 

Device

) before attempting to 

include

 it into the current Z-Wave Gateway/Control Panel. 

 

Removing Device (Exclusion) 

The  device  must be removed from existing Z-Wave  network before being included into another. There are two 
methods available to exclude a device. 

 

Exclusion Mode 

 

Put the Z-Wave Gateway or Control Panel into 

Exclusion mode

 (please refer to the Z-Wave Gateway or Control 

Panel manual). 

 

Within 1.5 seconds, press the Function Button 3 times and the device will be removed from the Z-Wave network. 

 

Factory Reset 

(Only use factory reset when network Control Panel/Gateway is missing or inoperable). 

 

Press and hold the Function Button of the device for 10 seconds to factory reset. 

<NOTE> 

 

Factory resetting the device will restore it to factory default settings (excluded from the Z-Wave network). 
The Z-Wave Gateway or Control Panel will still keep its Z-Wave settings. Please refer to the Gateway or 
Control Panel manual on how to remove the device’s Z-Wave settings. 

 

Factory resetting the device will also clear all accumulated power data. 

 

Range Test 

 

To test whether the device is able to communicate with the Z-Wave Gateway or Control Panel: 

 

Put the Gateway / Panel into range test mode (Walk Test). 

 

Press the Function Button on the device. 

 

The Gateway / Panel should display if the device is within the operation range (please refer to the operation 
manual of the Gateway / Panel). 

 

Z-Wave Router Device Capacity   

The  Power Switch  allows  other  Z-Wave  devices to join the Z-Wave  Network through the Router. The maximum 
capacity of the devices to join the Z-Wave Network through the Power Switch is 255. 

 

Operation 

 

Appliance Control 

 

After being included into a Z-Wave  Gateway or  Control Panel, plug a home appliance into the Power Switch. 
This home appliance’s power and energy usage data will be transferred to the Control Panel. 

 

Users can remotely turn on/off the electric appliance through the Control Panel (please refer your Control Panel 
manual). 

 

Pressing the Function Button on the Power Switch can also toggle on/off the Power Switch. 

 

The Power Switch transmits a signal with power data to Z-Wave Gateway/Panel every 10 minutes starting from 
the last time a signal is transmitted. 

 

When the Power Switch is re-plugged after it has been removed from the power outlet, the previous on/off status 
of Power Switch will be resumed immediately. 

 

Energy Consumption Monitor (PSM-29ZW only) 

 

If the power  output  is  below  1kW, PSM-29 will transmit a signal to Z-Wave  Gateway/Panel  when  the  power 
deviates by +/- 2W to update PSM-29’s power information.

 

 

If the power  output  is above 1kW, PSM-29 will transmit a signal to Z-Wave  Gateway/Panel  when  the power 
deviates by +/- 5W to update PSM-29’s power information. 

 

The Power Switch transmits a signal with power data to Z-Wave  Gateway/Panel  whenever power usage 
increases by 0.1kW/hr. 

 

When the power is below 20W, measurement error is more likely to occur. 

 

Power Specification 

 

For 

110V:

 the maximum operation load is 1760W and 16A. Warning: please do not exceed the maximum load.   

 

For 

230V:

 the maximum operation load is 3680W and 16A. Warning: please do not exceed the maximum load. 

 

If the Power Switch is overheating, it will cut off power automatically as a safety measure. The Power Switch 
must be un-plugged and re-plugged after cut off to resume normal operation. 

 

 

 

 