3
Meter CC, v2
Switch Binary CC
Supervision CC ,(S2)
Firmware Update Md CC ,(S2)
Z-Wave’s Groups (Association Command Class Version 2)
The Switch can be set to send reports to associated Z-Wave devices. It supports one association group with five
node support for Grouping 1. For grouping 1, the Switch will report its latest status to Z-Wave Gateway/Panel.
Group 1 for “LifeLine”: (max node : 5)
Switch Binary CC (COMMAND_CLASS_SWITCH_BINARY)
Meter CC (COMMAND_CLASS_METER)
Device Reset Locally CC (COMMAND_CLASS_DEVICE_RESET_LOCALLY)
Auto report to Grouping 1 (Maximum Node 5)
On/Off Event Report
When toggling between On/Off, it will send Binary Switch Report to the nodes of Grouping 1.
Factory Reset
When the Power Switch is reset to factory default, it will send Device Reset Locally to all nodes in Group 1.
Meter Report:
If the power output is below 1kW, PSM-DIN2 will transmit a signal to Z-Wave Gateway/Panel when the power
deviates by +/- 2W to update PSM-DIN2’s power information.
If the power output is above 1kW, PSM-DIN2 will transmit a signal to Z-Wave Gateway/Panel when the power
deviates by +/- 5W to update PSM-DIN2’s power information.
PSM-DIN2 transmits a signal with power data to Z-Wave Gateway/Control Panel every 10 minutes starting
from the last time a signal is transmitted.
The Power Switch transmits a signal with power data to Z-Wave Gateway/Control Panel whenever power
usage increases by 0.1kW/hr.
Data format:
Example 1:
41 64 00 00 50 14
FF FF
00 00 00 00
kWh (00005014 = 20500 = 20.5)
Present Value:
41 64 00 00 50 14
Previous Value:
00 00 00 00
Example 2:
41 74 00 00 27 10
FF FF
00 00 00 00
W (00002710 = 10000 = 10W)
Present Value:
41 74 00 00 27 10
Previous Value:
00 00 00 00