Figure 7.14: Anchor points near hatches in the spinner cover
1
Anchor points
Escape through the front hatches in the spinner must be considered the last
possibility. Escape through the rear service hatch instead is recommended.
7.4 Rescue route
0011461406
It is intended that normal access, evacuation routes, and escape routes can be used for rescue
depending on where the injured person is located in the wind turbine, the type of injury, and the
safety equipment which is used (e.g. stretcher or descent device).
Risk of being trapped in confined space! SPRA ID No. RW 24.76
• Always make sure that a service technician is on standby if there is an emergency
outside the entrance of the confined area.
• Obey the rules, procedures, and local requirements for confined spaces.
• Make sure that an emergency rescue plan is in place before the start of work.
Evacuation, escape and rescue instruction for onshore wind turbine
Document no.: 0067–2397 V00 · Class: RESTRICTED · Type: T09
Page 21 of 33
Summary of Contents for V105-3.45 MW
Page 33: ......