background image

5

Section 6:   FEATURES

x

 

In the beginning, cutting vinyl records used to require much more equipment and procedures. The VRX-
2000 allows you to record vinyl in a small space with minimum additional equipment.

x

 

The VRX-2000 has a newly designed stereo cutting head.  It does not require a big power amplifier.  It
operates with a built-in power amplifier.  The tracking arm also has a new design.

x

 

The blank disk has a capacity of 14 minutes of recording per side.

x

 

The VRX-2000 uses a delicate sapphire cutting stylus.  The life of the stylus is 200-300 minutes, varying
with the type of usage

.

Section 7:  BASIC KNOWLEGDE OF CUTTING MACHINE

7.1  Description of Each Part

x

Cutting arm

 - the cutting arm consists of two parts: the base and the arm.  The base has a mechanism

which moves the arm from the outside to inside of the vinyl as you record.  The VRX-2000 uses a DC
motor to rotate the gear and move the head in a constant speed.  In addition, the arm can be moved
quickly by using the manual rotation wheel, to move the head toward the specific location on the vinyl
blank where you would like to start recording, or to create a tail.

x

Turntable

 -  consists of a platter, platter weight, silicone mat, and disc holder.  The platter weight is very

heavy, facilitating consistent rotation.  The silicone mat and disc holder secure the disc on the turntable
solidly, and prevents shifting of the blank disc.  The turntable is driven by high torque direct drive AC
motor and generates a very stable rotation to record the music accurately.

x

Cutting Head

 – the cutting head translates the music signal to the physical movement of the stylus and

cuts the groove on the blank disc. The cutting head of the VRX-2000 uses the same moving coil
technology as top professional cutting machines from the past.  The cutting head has 2 magnetic
drivers separated by a 90 degree angle creating a V shape.  This layout is optimum for stereo signal
recording with the best possible channel separation, and best balance. The operation of the cutting
head is very similar to that of a loudspeaker – it consists of a coil and a magnet, and the coil moves as
the electric current is applied.  The coil is very intricate and fragile – improper handling or overloading
may burn the coil or damage the components.  Please be careful not to overload the coil and do not
touch or disassemble the cutting head – damage by improper usage will not be covered by warranty
service.

x

Cutting Stylus

 – the cutting stylus of the VRX-2000 uses a sapphire tip. The sapphire tip is very

delicate and requires careful handling.  The cutting head has a heater line to apply heat to the sapphire
tip while recording.  The heater line is very thin and easily damaged; it requires careful handling and
setting up.  Please do not use this cutting stylus for any other purpose.

x

Cutting Equalizer

 – An analogue record is recorded using RIAA equalizer, in order to allow the vinyl to

hold a wide frequency range.  The VRX-2000 has an RIAA equalizer built in.  This equalizer decreases
the low end and increases the high end for the recording process.  On playback, the phono EQ will
automatically adjust to restore the original signal.

Summary of Contents for VRX-2000

Page 1: ...imes have very wide frequency ranges and have not been prepared professionally for mass production or broadcast Please study and understand compressors and limiters and how to use equalizers to get th...

Page 2: ...ll be recorded on the vinyl Unstable surfaces may also cause platter rotation fluctuations Please avoid sunlight dust humidity and do not place the unit near heating appliances or sources of heat If d...

Page 3: ...handling or recording 3 4 TRACKING ARM The VRX 2000 tracking arm is another fragile component and is and very accurately made Please do not put pressure on the tracking arm as it may cause inaccuraci...

Page 4: ...the box Please fill out the card in full and send it to Vestax customer support in or nearest to your country Vestax will not be able to service or support the unit if it is not registered If you have...

Page 5: ...ble rotation to record the music accurately x Cutting Head the cutting head translates the music signal to the physical movement of the stylus and cuts the groove on the blank disc The cutting head of...

Page 6: ...6 Section 8 Description of VRX 2000 Components 8 1 Top Panel...

Page 7: ...visual display of the level of heat applied to the cutting stylus 12 Heater current adjustment control adjusts the level of the heat applied to the cutting stylus 13 VU level meters a display of the...

Page 8: ...hono level output jacks standard RCA left right output jacks for playback 31 On off power switch 32 AC power cable 33 Ground terminal 34 XLR balanced left right audio input sockets PIN1 ground PIN2 ho...

Page 9: ...counter weight qty 1 x Playback tone arm headshell qty 1 x Ioniser qty 1 screws qty 2 x Stereo RCA cable qty 1 x Ground cable qty 1 x Extra fine scale to measure weight of cutting arm qty 1 x record...

Page 10: ...ressure to firmly secure the vinyl blank to the silicone mat 5 Screw disc holder and secure blank x If the blank disc is not dust free it may create skipping or noise problems Ensure your blank is per...

Page 11: ...secure the stylus shaft Do not over tighten and do not tighten screw a and then screw b independently Please make sure that the stylus shaft and cutting stylus are correctly aligned with the receptor...

Page 12: ...ide the cutting head into the arm from the front 2 Using the screwdriver secure the cutting head on the cutting arm with supplied two screws N B x Please ensure the cutting head is totally secured or...

Page 13: ...rear of Ioniser mechanism Select high Please refer Figure12 1 A 7 Rotate the slider cam and release lock of the cutting arm See Figure 12 1 B 8 Set the input level control to minimum and heater contro...

Page 14: ...nyl off cuts away form the cutting stylus Try to make the vinyl off cuts wind around the center spindle disc holder This will reduce the amount of brush action required Please refer to Figure 12 1 D C...

Page 15: ...s temperature is too low d If the off cut breaks as you record the stylus temperature is too high f 4 Cutting in this way requires experience Please take your time and be patient using test blanks to...

Page 16: ...of information http mpaonline org uk Music Publishers Association copyright law VESTAX CUSTOMER SERVICE CENTRES Vestax Japan Head Office 1 18 6 Wakabayashi Setagaya ku Tokyo 154 0023 Japan Fax Interna...

Reviews: