Electrical System Specifications:
This hydraulic drum crusher, model HDC-900 or HDC-905, was tested at the factory at the
voltage specified at the time of order. For applications that require voltages that differ from
original specifications, the motor and control transformer must be rewired for the appropriate
voltage. Failure to do so automatically voids the “Limited Warranty” (see p. 12A & 12B) and
might significantly damage the electrical system.
Motor wiring:
The table below indicates how to wire 3-phase motors of specified voltages.
208-230VAC, 3-Phase
460VAC, 3-Phase
Motor wires 1 & 7
Connect to contactor
lead T1
Motor wire 1
Connect to contactor
lead T1
Motor wires 2 & 8
Connect to contactor
lead T2
Motor wire 2
Connect to contactor
lead T2
Motor wires 3 & 9
Connect to contactor
lead T3
Motor wire 3
Connect to contactor
lead T3
Motor wires 4, 5 & 6
Tie together with a wire
nut
Motor wires 4 & 7
Tie together with a wire
nut
Motor wires 5 & 8
Tie together with a wire
nut
Motor wires 6 & 9
Tie together with a wire
nut
Transformer:
If the supply voltage to the motor is changed, the primary wires of the transformer must also be changed
(refer to “Electrical system diagram” on p. 8; also refer to the label on the transformer to properly connect
to the supply voltage).
Page 9
Summary of Contents for HDC-900
Page 8: ...6 33 72 35 6 17 Page 7A SORGHG 3DUWV LDJUDP RI 3RZHU 8QLW...
Page 13: ...Page 8 FIG 9 Electrical system diagram...
Page 15: ...M 14 2 4 3 1 12 11 7 8 13 15 9 6 10 5 16 Page 10 FIG 10 Hydraulic System Diagram...
Page 16: ...Data Label 221 305 206 220 248 251 By Oil Fill 300 203 2 Page 11 Label placement diagram...