VC series bench scales Technical Manual
-
9 -
Press
key.
Li-LO
appears at Weighing display, and low limit value
shows that currently set at Piece. W display. Press
key.
Li-HI
appears
at Weighing display, and high limit value shows that currently set at UNIT.W
display. Press
key. Go back to working area.
In case that only one point (13.Pn. 1) is selected to set, low limit value shows
after press
key at once go back to working area.
5.5.3 Comparing ( how limit function work )
Suppose two limits have been set;
When the quantity is under the low value, it is ranked as “ LO “
When the qua
ntity is between the low value and the high, it is ranked as “ OK “
When the quantity is over the high value, it is ranked as “ HI “
Notes
# Such settings as lower limit value >= Higher limit value will be error.
# Comparative judgment condition;
At one point(13.Pn. 1) :
L O : v a l u e < lower limit.
OK: lower limit =< value.
At two point(13.Pn. 2) :
LO: value < lower limit
OK: lower limit =< value =< higher limit
HI : higher limit< value
# We get beep sound in response to comparing result.
The condition is selectable by function set.
SECTION 6 FUNCTION SETTING AND CALIBRATE
6. 1 Enter function setting mode
1) Hold
key until LOW/TOTAL
display shows “
FSET
“ . followed by F0 SEL
2) To change setting parameter, press
or
key
3) To confirm setting change and forward to the title, press
key.