VC series bench scales Technical Manual
- 18 -
(1)Command
Consists of 2 words (ASCII code)
(2)Value parameter
①
Unit weight value setting
7 pieces of number and one decimal point(
「.
」
:
2EH)
(
N1 to N8
:
number
・
decimal point
)
②
Lower limit & Upper limit
value setting
Polarity
(
「+」
:
2BH
,
「-」
:
2DH
)
and a number
(
P1: polarity
「
+
」
,
「
-
」
)
(
N1 to N7
:
number
・
decimal point
)
8.4.3
Reply output
(1)Reply output format
Consists of 5 words, including terminator(CR
=
0DH
,
LF
=
0AH)
(2)Relay output list
A1 A2 A3
Code
Contents
A
0
0
41H 30H 30H Proper completion
E
0
1
45H 30H 31H Command error (Wrong command received)
、
other errors
E
0
2
45H 30H 32H Value format error(Too much digit, No data, etc.)
E
1
0
45H 31H 30H
The set unit weight value is error
、
No memory of
unit weight
E
1
2
45H 31H 32H Limit function is not under operation
8.4.4
Tare (Zero adjustment)command
Command
Contents
ParameterAddress
・
Value
Response
C1 C2
Code
T
△
54H 20H Tare(Zero
adjustment)
command
Nil
A00:Proper completion
E01:Tare disable due to
error of weight value
1 2
C1 C2
1
2
3
4
5
6
7
8
N! N2 N3 N4 N5 N6 N7 N8
1
2
3
4
5
6
7 8
P1 N1 N2 N3 N4 N5 N6 N7
1
2
3
4
5
A1 A2 A3 CR LF