44
5
Remove the drain plug
• Close the seacock and detach the
water inlet hose from the sea water
pump.
• Drain the coolant: To do this, remove
the drain plug from the heat exchanger
housing.
• Remove the filler cap from the top of the
heat exchanger housing to allow air into
the system and check that all coolant
has drained off.
• Remove the alternator.
Removal of bolts out of the end covers
Take out both central bolts from the end
covers and take the end covers with the O-
rings out of the housing.
Maintenance
Cleaning the heat exchanger
VD01018
VD01019
VD01003
13