Installation manual VF4 VF5
4.5 Exhaust system for stern drive version
IMPORTANT:
It is the responsibility of the boat manufacturer or installing dealer to properly locate
the engine and install the exhaust system.
Improper installation may allow water to enter the exhaust manifolds and combustion chambers and severely
damage the engine. Damage caused by water in the engine will not be covered by Warranty, unless this dam-
age is the result of defective part(s).
Verify that the riser provides the required dimension “c,” or a distance greater than “c,” as indicated.
Model
VF5-VF4
“c” Must be at least 580 mm (23 inches)
Engine With Standard Riser
a - From Waterline To Top Of Transom
b - From Highest Point On Exhaust Riser To Top Of Transom
c - From “a” Minus “b” (from water line to the highest point of the riser )
d - Waterline At Rest