www.fmiproducts.com
123095-01C
27
Figure 48 - Correct Pilot Flame Pattern
1/8"
(0.3 cm)
3/8" - 1/2"
(0.95 cm -
1.3 cm)
1/2"
(12.7 mm)
3/4"
(19 mm)
Edge of Burner
Top of Burner
Figure 49 - Correct Ignitor Location
(Side View)
DECORATIVE FACING
Any noncombustible material may be used
for facing (glass, tile, brick, etc.) as long as
the proper clearances are observed (see
Clearances
, page 7).
IMPORTANT:
Louvered
openings must not be obstructed, and upper
and lower panels must remain removable for
servicing. Use only heat resistant, noncom-
bustible mortar or adhesive when securing
facing material.
Note: Combustible material, such as wood,
that has been fireproofed is not considered
noncombustible.
FIREPLACE INSTALLATION
Continued
PILOT/ELECTRODE ASSEMBLY ADJUSTMENT
The pilot assembly is factory preset for the
proper flame height. Alteration to these set
-
tings may have occurred during shipping
and handling. If this is the case, some minor
adjustment may be necessary and should be
done by a qualified technician. To access pilot
assembly, glass door must be opened. The
proper settings for thermopile height should
be at a distance of 3/8" to 1/2" from pilot flame
as shown in Figure 48.
The electrode is installed at the factory for
proper positioning. However, alterations to
position may have occurred due to shipping
and handling. These settings may need
adjustment and must be done by a qualified
technician. The correct position and height is
as shown in Figure 49.
Left
Front
Right
Back
B
B
A
A
Figure 46 - Installing Logs “B ” (Top View)
Left
Right
Back
Front
D
C
C
D
E
Figure 47 - Installing Twigs “C, D, E ”
(Top View)