8. Specifications
8
.
1
General Specificatins for Motors
※1 Motor insulation is recognized as Class A
(105
℃
) by UL and CSA standards.
8
.
2
Driver Specifications
※2
The rated current value is determined by using a regulated power supply, which has an output impedance of nearly 0
Ω.
In the case of commercial power source, please refer to the load torque-driver input current characteristics on page 21.
Specification
100M
Ω
or more when 500V DC is applied between protective earth terminal and power supply
terminals (I/O terminals) .
Sufficient to withstand 3.0 kV at 50Hz applied between power supply terminal (I/O terminals) and
I/O terminals for 1 minute, and 1.8kV at 50Hz applied between protective earth terminal and power
supply terminals.
85
%
max. (no condensation)
IP10
Operating
Storage
Transport
0℃〜+50℃
−25℃〜+70℃
−25℃〜+70℃
Operating
Storage
Transport
1000m max.
3000m max.
3000m max.
Item
Insulation resistance
Dielectric strength
Temperature rise
Insulation class
※1
Temperature
Humidity
Altitude
IP class
23
Specification
100M
Ω
or more when 500V DC is applied between the windings and the frame.
Sufficient to withstand 1.5kV at 50Hz applied between the windings and the frame for 1
minute.
Temperature rise of the coil measured by the Thermocouple Method is 60
℃
or less after the
rated range of operation.(
□
165
×
165
, 5
think Aluminum heat sink attached)
Class E (120
℃
)
85
%
max. (no condensation)
IP40
Operating
Storage
Transport
0℃〜+50℃
−25℃〜+70℃
−25℃〜+70℃
Operating
Storage
Transport
1000m max.
3000m max.
3000m max.
Item
Model
Input power
Rated current
※2
Speed range
Insulation resistance
Dielectric strength
Temperature
Humidity
Altitude
IP class
FBLD75AW
FBLD120AW
FBLD75CW
FBLD120CW
FBLD75SW
FBLD120SW
Single phase 100V-115V
±
10% 50/60Hz
Single phase 200V-230V
±
10% 50/60Hz
Three phase 200V-230V
±
10% 50/60Hz
2.3A
3.0A
1.4A
1.8A
0.75A
1.0A
300
〜