AUTOMIX 10 (EN) 0508 

AUTOMIX 10 

 

MOUNTING AND OPERATING INSTRUCTIONS 

 

GENERAL FUNCTIONS 

 

AUTOMIX 10 is an advanced electronic temperature control for hydronic radiator and radiant floor  

heating systems. It can easily be integrated into an existing heating system. The main supply and all 

sensors have plug-in connections. The quick do-it-your-self installation saves on labor charges.  

 

AUTOMIX 10 works continuously and proportionally. Through impulses from the sensors the controller 

directs the motor to keep the valve plug in the position that corresponds to the actual heat requirement  

of the house. 

 

DELIVERY PARTS OF ART.NO 1210 

 

1.  Valve motor AUTOMIX 10 with built-in electronics and mounting kit 

2.  Adapter 230/18 VAC 200 mA with 1,7 m wire 

3.  Supply water sensor T1 with 1 m wire 

4.  Outdoor sensor T2 with 15 m wire 

 

OPTIONALS 

 

5.  Room sensor AUTOMIX 10RB with 15 m wire, art.no 1211 
AUTOMIX 10RB should be installed if the room temperature of the house fluctuates because the building is 

affected by e.g. sunlight or wind. With AUTOMIX 10 RB the room temperature can be set between 12°C and 

27°C. 

 

6.  Remote control AUTOMIX 10RC with 15 m wire, art.no 1212 
Remote control AUTOMIX 10RC is designed for floor heating systems. The remote control provides a 

convenient way to adjust the supply water temperature without going to the boiler room.  

 

 

MOUNTING 

 

Supply water sensor T1 

 

Supply water sensor T1 is fastened to a non-insulated part of the supply pipe after the mixing valve. 

For optimum temperature measuring the pipe and sensor have to be insulated afterwards. 

 

Outdoor sensor T2 

 

Outdoor sensor T2 is to be mounted on the north or northwestern outside wall at least 3 metres above 

ground. The outdoor sensor must never be mounted above a window or near an air valve as this  

would influence the sensor. 

 

Room sensor AUTOMIX 10RB 

 

Room sensor AUTOMIX 10RB is mounted at a place with an average temperature of the house. The room 

sensor should not be placed where it can be affected by direct sunlight, heat radiation or draught. Radiators 

with a thermostatic valve in the same room as the room sensor must be max. opened to obtain a correct 

temperature control. 

 

Remote control AUTOMIX 10RC 

 

Remote control AUTOMIX 10RC is mounted at a convenient place for operating. 

Summary of Contents for AUTOMIX 10

Page 1: ...UTOMIX 10 RB the room temperature can be set between 12 C and 27 C 6 Remote control AUTOMIX 10RC with 15 m wire art no 1212 Remote control AUTOMIX 10RC is designed for floor heating systems The remote control provides a convenient way to adjust the supply water temperature without going to the boiler room MOUNTING Supply water sensor T1 Supply water sensor T1 is fastened to a non insulated part of...

Page 2: ...ckwise position Turn scale E according to the open closed direction of the valve 5 Place handle F onto the motor ensuring that the arrow points to the left end position of the scale Tighten the whole unit by means of screw G 6 Using a screwdriver No 3 turn the disengaging button H from A to HAND position and rotate the valve with handle F from one end position to the other It is important that the...

Page 3: ...have plug in connections The quick do it your self installation minimizes installation problems Left side of motor A Adapter B Supply water sensor T1 Right side of motor C Outdoor sensor T2 D Graphs Motor under the cover Connection E is placed under the motor cover Room sensor AUTOMIX 10RB and remote control AUTOMIX 10RC are connected to E The cover has edge cuttings for the wire ...

Page 4: ...temperature rise with falling outdoor temperature lower knob D raise knob F Should the room temperature fall with falling outdoor temperature raise knob D lower knob F Make only minor changes with knobs D and F When the house has an even room temperature despite fluctuating outdoor temperatures the correct regulating graph has been obtained N B Heat affects slowly When a temperature setting has be...

Page 5: ...y water temperature is selected with knob C In the example graph 3 has been selected and the min supply water temperature is set to 22 C Max supply water temperature will automatically be 40 C Setting of max supply water temperature is used in hydronic radiator heating systems Max supply water temperature is selected with knob C In the example graph 6 has been selected Max supply water temperature...

Page 6: ...parallel displacement F A green LED indicates that power is on When the motor runs the LED dims slightly TECHNICAL DATA Type of control PI control with microprocessor Voltage 18 VAC 50 60 Hz Adapter 230 18 VAC 200 mA with 1 7 m wire Power consumption 3 VA Torque 5 Nm Angle of rotation 90 Heating graphs 1 to 9 stepless Parallel displacement 10 C supply water temperature stepless Min supply water li...

Reviews: