background image

AUTOMIX 10 (EN) 0508 

OPTIONALS 

 

 

 

 

 

AUTOMIX 10RB is a room sensor for measuring and setting the 

temperature inside the house. 

 

AUTOMIX 10RB should be installed if the room temperature 

fluctuates because the building is affected by sunlight or wind. 

 

A green LED indicates that power is on. When the motor runs, the  

LED dims slightly. 

 

 

 

 

 

 

 

 

 

AUTOMIX 10RC is a remote control designed for floor heating 

systems. It is used to conveniently adjust/parallel displace the   

heating graph. Supply water temperaure can be lowered 9°C  

or raised 6°C. AUTOMIX 10RC corresponds to the function 

parallel displacement F. 

 

A green LED indicates that power is on. When the motor runs, the  

LED dims slightly. 

 

 

 

 

 

 

 

TECHNICAL DATA 

 

Type of control 

PI-control with microprocessor 

Voltage 

18 VAC 50/60 Hz 

Adapter 

230/18 VAC 200 mA with 1,7 m wire 

Power consumption 

3 VA 

Torque 

5 Nm 

Angle of rotation 

90° 

Heating graphs 

1 to 9, stepless 

Parallel displacement 

+/- 10°C supply water temperature, stepless 

Min. supply water limiter 

+15°C to +35°C supply water temperature 

Max.supply water limiter 

+40°C to +90°C supply water temperature 

Room sensor AM 10RB 

+12°C to +27°C room temperature, stepless 

Remote control AM 10RC 

-9°C to +6°C supply water temperature, stepless 

Manual operation 

Yes, in case of power failure 

Prtotection class 

IP 40 

Dimensions 

77 x 90 x 90 mm 

Weight 

0,53 kg 

 

 

 

 

www.acaso.se 

Summary of Contents for AUTOMIX 10

Page 1: ...UTOMIX 10 RB the room temperature can be set between 12 C and 27 C 6 Remote control AUTOMIX 10RC with 15 m wire art no 1212 Remote control AUTOMIX 10RC is designed for floor heating systems The remote control provides a convenient way to adjust the supply water temperature without going to the boiler room MOUNTING Supply water sensor T1 Supply water sensor T1 is fastened to a non insulated part of...

Page 2: ...ckwise position Turn scale E according to the open closed direction of the valve 5 Place handle F onto the motor ensuring that the arrow points to the left end position of the scale Tighten the whole unit by means of screw G 6 Using a screwdriver No 3 turn the disengaging button H from A to HAND position and rotate the valve with handle F from one end position to the other It is important that the...

Page 3: ...have plug in connections The quick do it your self installation minimizes installation problems Left side of motor A Adapter B Supply water sensor T1 Right side of motor C Outdoor sensor T2 D Graphs Motor under the cover Connection E is placed under the motor cover Room sensor AUTOMIX 10RB and remote control AUTOMIX 10RC are connected to E The cover has edge cuttings for the wire ...

Page 4: ...temperature rise with falling outdoor temperature lower knob D raise knob F Should the room temperature fall with falling outdoor temperature raise knob D lower knob F Make only minor changes with knobs D and F When the house has an even room temperature despite fluctuating outdoor temperatures the correct regulating graph has been obtained N B Heat affects slowly When a temperature setting has be...

Page 5: ...y water temperature is selected with knob C In the example graph 3 has been selected and the min supply water temperature is set to 22 C Max supply water temperature will automatically be 40 C Setting of max supply water temperature is used in hydronic radiator heating systems Max supply water temperature is selected with knob C In the example graph 6 has been selected Max supply water temperature...

Page 6: ...parallel displacement F A green LED indicates that power is on When the motor runs the LED dims slightly TECHNICAL DATA Type of control PI control with microprocessor Voltage 18 VAC 50 60 Hz Adapter 230 18 VAC 200 mA with 1 7 m wire Power consumption 3 VA Torque 5 Nm Angle of rotation 90 Heating graphs 1 to 9 stepless Parallel displacement 10 C supply water temperature stepless Min supply water li...