REPLACEMENT PARTS

1. Circuit Board for CC-25B

2. Sensor Probe

3. Hose clamp

4. Circuit Board CC-50

5. Tubing Adaptor 

6. Fuse 

(F12a)

LIMITED WARRANTY

Commodity Axis Inc. warrants that ViaAqua® Chiller is free from defects for a period of one 

year from the initial date of purchase shown in the original cash register receipt. Commodity 

Axis Inc. disclaims all other warranties of merchantability and/or fitness for a particular 

purpose. Although this limited warranty gives you specific rights, you may have other rights 

that may vary from state to state. This Warranty is void if the failure of the ViaAqua® Chiller 

or any part, sealant or component there of is due to (i) misuse, (ii) tampering, (iii) negligence, 

(iv) misapplication, (v) abuse, (vi) accident and/or (vii) failure to properly (a) maintain, (b) 

clean, (c) pre-filter, (d) reassemble, (e) clean and/or use the ViaAqua® Chiller with a Ground 

Fault Circuit Interrupter (GFCI).

CONSUMER REMEDIES

Commodity Axis Inc. entire Liability and your sole exclusive remedy are either repair or 

replacement of the Via Aqua® chiller only if you return the defective Via Aqua® chiller 

directly to Commodity Axis Inc. with the original receipt in this original box along with 

$25.00 for shipping and handling. Do not send the chiller by insured mail. The chiller may 

be sent by UPS requiring signature upon arrival. Any replacement Via Aqua® chiller will 

be warranted for remaining of the original warranty period. In not event shall any shipping 

charges be reimbursed. In no event will Commodity Axis, Inc. be liable for any consequential 

or incidental damages including, but not limited to, loss of life, personal injury, property 

damage, damaged equipment, lost profits, lost wages, lost savings, lost income, etc. 

arising out of the use of the ViaAqua® chiller. Some states do not allow for the limitation or 

exclusion of liability for incidental or consequential damages, so the above exclusion may 

not apply to you.

For model CC-25B

For model CC-50

Summary of Contents for Polar Bear Chiller CC-25B

Page 1: ...sy to program digital thermostat Compact efficient design Maximum cooling efficiency For fresh or saltwater environments WARNING Buyer User assumes all responsability for safety and proper use not in...

Page 2: ...drip loop must be used when plug into any electrical devices A drip loop is part of the cord hanging below the receptacle The national code requires all aquarium equipment to be plugged into a G F C...

Page 3: ...rify that there are not any kinks in the tubing supplying water to the chiller or in the output tube returning water to the aquarium or sump 9 Turn on water pump or water supply 10 Check all connectio...

Page 4: ...l for the aquarium There is not a minimum of 10 clearance around the chiller for adequate ventilation The chiller is installed inside an aquarium stand Problem Too much noise The chiller must be place...

Page 5: ...move the zip ties holding the sensor wire 9 Disconnect the sensor from the temperature controller 10 Install new sensor Use Teflon tape on the compression nut 11 Secure sensor wire with new zip ties c...

Page 6: ...the compression nut onto the new senor if not already installed 19 Now reconnect the new sensor to board 20 Secure the sensor back into the heat exchanger 21 Secure all wiring and insulation with zip...

Page 7: ...t Circuit Interrupter GFCI CONSUMER REMEDIES Commodity Axis Inc entire Liability and your sole exclusive remedy are either repair or replacement of the Via Aqua chiller only if you return the defectiv...

Page 8: ...card and proof of purchase within 15 days of purchase to Commodity Axis Inc 300 South Lewis Rd Unit J Camarillo CA 93012 IMPORTANT Please make a copy of this warranty card and retain it for your reco...