background image

 

6

3.2 

Safety and regulation elements  

 

Both  reservoirs  have  their  control  panels  equipped  with  a  thermometer  and  regulation  thermostat  on  which 
the service water required temperature can be set. 
In case of a reservoir combined with boiler controlled by an equithermal Honeywell AQ 6000 regulation (or by 
other  superior  automatics  which  at  the  same  time  controls  the  hot  service  water  heating  process),  it  is 
necessary to disqualify the heater from operation and use a thermostat delivered together with automatics.  
 

3.3 

Electric wiring diagram 

 

ϑ

 

 

OV 100 L elementary wiring diagram 

OV 100 L wiring diagram –  

Fig. no. 2 

Electric wiring diagram of VIADRUS OV 100 L heater 

 

4. 

Installation regulations 

4.1 

Regulations and directives  

 

The heater positioning must comply with the safety connection: 

a) regarding the heating system  

Č

SN 06 0310 

Heating systems in buildings – Designing and installation  

Č

SN 06 0830 

Heating systems in buildings – protecting device 

b) regarding the electric network  

Č

SN 33 2180 

Electrical regulations. Connection of electrical devices and appliances. 

c) regarding the HWS heating 

Č

SN 06 0320 

Heating systems in buildings – Hot water preparation – Designing and planning 

Č

SN 06 0830 

Heating systems in buildings – Safety devices. 

Č

SN 73 6660 

House water plumbing  

Č

SN 07 7401 

Water and steam for thermal energy equipments with working pressure up to 8 MPa 

Č

SN 06 1010 

Stack  water  heaters  with  water  and  steam  heating  combined  with  electric  heating 
Technical requirements. Testing.. 

Č

SN 75 7111 

Waters quality. Drinking water. 

Č

SN 83 0616 

Hot service water quality  

 
 

ELECTRIC PANEL 

REAR PART 

Summary of Contents for OV 100 L

Page 1: ...Hercules U26 Návod k obsluze VIADRUS OV 100 L MANUAL FOR OPERATION AND INSTALLATION ...

Page 2: ...gulations 6 4 1 Regulations and directives 6 4 2 Summary of hot service water consumption 7 5 Order delivery and assembly 7 5 1 Order 7 5 2 Delivery and accessories 7 5 3 Assembly procedure 8 5 4 Heaters filling with water procedure 9 6 Heaters operation by users 9 7 IMPORTANT WARNINGS 9 8 Maintenance 10 9 Instructions for product disposal after its service life expiration 10 10 Guarantee and liab...

Page 3: ...CO possibly VIADRUS CLAUDIUS K 2 Its design corresponds to design of boilers and the boiler electric connection enables a preferential HWS heating Accumulation water heater advantages 1 Uniform heating 2 Internal surface protected by double layer of enamel 3 Adjustable service water temperature 4 Economical operation 5 Service water heated quickly 6 Easy assembly and operation 7 Compared to the fl...

Page 4: ...water heating and its flow are valid in case that a Grundfos pump is connected to the heating system and its revolutions switch is in position 3 which corresponds to 720 l h If the pump works with lower revolutions smaller flow quantity the time of heating the service water will be prolonged IMPORTANT WARNINGS Set the thermostat of the heater to max 60 C temperature note The regulations in the Cze...

Page 5: ...es and there is screwed the anode protective rod plus the hot service water input and output Heating water input and output are at the back of the heater The heat loss is reduced markedly by the foam polyurethane insulation Fig no 1 VIADRUS OV 100 L heater assembly dimensions in mm In case of the stationary VIADRUS OV 100 L heater in the lower part of the vessel there is positioned the discharge h...

Page 6: ...1 Regulations and directives The heater positioning must comply with the safety connection a regarding the heating system ČSN 06 0310 Heating systems in buildings Designing and installation ČSN 06 0830 Heating systems in buildings protecting device b regarding the electric network ČSN 33 2180 Electrical regulations Connection of electrical devices and appliances c regarding the HWS heating ČSN 06 ...

Page 7: ... 3 persons per day 20 4 persons per day 24 The temperature is considered for a given hot water temperature by mixing it with cold water of approx 12 C temperature 5 Order delivery and assembly 5 1 Order In an order it is necessary to specify the data as follows Type of heater Demands on the parts ordered optionally 5 2 Delivery and accessories The heater is delivered while fixed on a pallet wrappe...

Page 8: ...d a pressure gauge It is allowed to use a combined fitting consisting of a safety and clack valves The safety valve must be connected in a way making sure that he longitudinal axis of the valve is in the horizontal position The valve discharge pipe is to be taken out into the effluent conduit If the pressure in inlet piping exceeds 630 kPa 6 3 bar applicable also to a transitory condition then a r...

Page 9: ...el 7 IMPORTANT WARNINGS 1 The appliance only can be used for the purpose that it is destined for 2 The appliance can only be operated by adult persons and children without being supervised by adults must not be left nearby the appliance 3 The appliance is not destined for the use by persons incl children whose physical sensual or mental disability or lack of experience and knowledge prevent them f...

Page 10: ... single usage and no longer can be used as a product Its disposal is subject to Act 477 2001 Sb a 185 2001 Coll as amended In case that the product has lost its serviceability you can take advantage of product take back service if this is established in case that the originator has declared that it is a scrap it must be handled according to the valid legislation of relevant country 10 Guarantee an...

Page 11: ... unit EN 13429 2000 NO 3 1 Recovery by material recycling ensure recyclability in all term sof the standard for the functional packaging unit EN 13430 2000 YES 3 2 Recovery in the form of energy ensure that calorific gain is achievable for the functional packaging unit EN 13431 2000 YES Iron NO 3 3 Recovery by composting ensure compost ability in all terms of the standard for the functional packag...

Page 12: ...12 ...

Page 13: ...g systems in buildings protecting device VIADRUS a s provides the guarantee during 24 months after the date when product was sold the end user The heater will be installed by a contractual service organization The completeness according to Manual for operation and installation is guaranteed by the contractual service organization The guarantee certificate is invalid without having been filled in T...

Page 14: ...e certificate for customer the user Record of accomplished guarantee and after guarantee repairs and regular product checks Record date Carried out activity Contracting service organization stamp signature Customer s signature ...

Page 15: ...830 Heating systems in buildings protecting device VIADRUS a s provides the guarantee during 24 months after the date when product was sold the end user The heater will be installed by a contractual service organization The completeness according to Manual for operation and installation is guaranteed by the contractual service organization The guarantee certificate is invalid without having been f...

Page 16: ...16 ...

Page 17: ...ating systems in buildings protecting device VIADRUS a s provides the guarantee during 24 months after the date when product was sold the end user The heater will be installed by a contractual service organization The completeness according to Manual for operation and installation is guaranteed by the contractual service organization The guarantee certificate is invalid without having been filled ...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...20 Date of revision 46 2012 ND GB ...

Reviews: