5.4 

Heaters filling with water procedure  

 

1. 

Open the combination faucet  

2. 

As  soon  as  the  water  at  the  draw-off  point  starts  run  out  of  the  hot  water  valve  the  filling  process  is 
completed and the combination faucet must be closed. 

3. 

Check the joints tightness. 

 

Warning: 

In case that Honeywell V 4044F three way valve is used it is necessary to reset the lever for manual 

valve operation from AUTO position into OPEN position. This must be done before the heating 

system filling process starts in order to bleed the heater. After the filling process has been completed 

reset again manually this lever back from OPEN into AUTO position. 

 

6. 

Heaters operation by users  

 

1. 

Set the required hot service water temperature on the heater thermostat. In order to ensure a sufficiently 
quick HWS heating we recommend to keep the 15 °C difference between the temperatures set on the 
heater and boiler thermostats (like the heater thermostat on 55 °C level and boiler thermostat on 70 °C 
level). In order to inhibit the propagation of legionella (bacteria coming up in backwaters at temperatures 
below 60 °C) we recommend to set the HWS temperature above 65 °C at least once a week. 

2. 

Keep checking the service water temperature on the thermometer. 

 

heater thermostat   network module  thermometer 

 

Fig. no. 4 

VIADRUS OV 100 L heater control panel  

 

7. 

IMPORTANT WARNINGS 

 

1. 

The appliance only can be used for the purpose that it is destined for.  

2. 

The appliance can only be operated by adult persons and children without being supervised by 
adults must not be left nearby the appliance. 

3. 

The appliance is not destined for the use by persons (incl. children) whose physical, sensual or 
mental  disability  or  lack  of  experience  and  knowledge  prevent  them  from  a  safe  use  of  the 
appliance unless they are supervised or if they were not instructed on the use of appliance by a 
person responsible for their safety.  

4. 

Children should be supervised in order to ensure that they do not play with the appliance. 

5. 

If the appliance is going to be put out of operation for a long time it must be disconnected from 
the electricity- from the socket. 

6. 

During  assembly,  installation  and  operation  of  the  appliance  it  is  necessary  to  comply  with 
standards that apply in the relevant country of destination. 

7. 

The  user  is  obliged  to  put  a  professional  contractual  service  accredited  by  VIADRUS  a.s.,  the 
heater  manufacturer  in  trust  with  commissioning,  regular  maintenance  and  defects elimination, 
otherwise the heater proper function isn’t guaranteed. „Quality and completeness certificate for 
VIADRUS  OV  100  L  heater“  after  having  been  filled  out  by  contractual  service  organization 
serves as the „Guarantee certificate“.
 

8. 

Regular maintenance on the heater must be done once a year according to the following chapter

If you don’t adhere to these terms you cannot claim for guarantee repairs.  

Summary of Contents for OV 100 L

Page 1: ...Hercules U26 Návod k obsluze VIADRUS OV 100 L MANUAL FOR OPERATION AND INSTALLATION ...

Page 2: ...gulations 6 4 1 Regulations and directives 6 4 2 Summary of hot service water consumption 7 5 Order delivery and assembly 7 5 1 Order 7 5 2 Delivery and accessories 7 5 3 Assembly procedure 8 5 4 Heaters filling with water procedure 9 6 Heaters operation by users 9 7 IMPORTANT WARNINGS 9 8 Maintenance 10 9 Instructions for product disposal after its service life expiration 10 10 Guarantee and liab...

Page 3: ...CO possibly VIADRUS CLAUDIUS K 2 Its design corresponds to design of boilers and the boiler electric connection enables a preferential HWS heating Accumulation water heater advantages 1 Uniform heating 2 Internal surface protected by double layer of enamel 3 Adjustable service water temperature 4 Economical operation 5 Service water heated quickly 6 Easy assembly and operation 7 Compared to the fl...

Page 4: ...water heating and its flow are valid in case that a Grundfos pump is connected to the heating system and its revolutions switch is in position 3 which corresponds to 720 l h If the pump works with lower revolutions smaller flow quantity the time of heating the service water will be prolonged IMPORTANT WARNINGS Set the thermostat of the heater to max 60 C temperature note The regulations in the Cze...

Page 5: ...es and there is screwed the anode protective rod plus the hot service water input and output Heating water input and output are at the back of the heater The heat loss is reduced markedly by the foam polyurethane insulation Fig no 1 VIADRUS OV 100 L heater assembly dimensions in mm In case of the stationary VIADRUS OV 100 L heater in the lower part of the vessel there is positioned the discharge h...

Page 6: ...1 Regulations and directives The heater positioning must comply with the safety connection a regarding the heating system ČSN 06 0310 Heating systems in buildings Designing and installation ČSN 06 0830 Heating systems in buildings protecting device b regarding the electric network ČSN 33 2180 Electrical regulations Connection of electrical devices and appliances c regarding the HWS heating ČSN 06 ...

Page 7: ... 3 persons per day 20 4 persons per day 24 The temperature is considered for a given hot water temperature by mixing it with cold water of approx 12 C temperature 5 Order delivery and assembly 5 1 Order In an order it is necessary to specify the data as follows Type of heater Demands on the parts ordered optionally 5 2 Delivery and accessories The heater is delivered while fixed on a pallet wrappe...

Page 8: ...d a pressure gauge It is allowed to use a combined fitting consisting of a safety and clack valves The safety valve must be connected in a way making sure that he longitudinal axis of the valve is in the horizontal position The valve discharge pipe is to be taken out into the effluent conduit If the pressure in inlet piping exceeds 630 kPa 6 3 bar applicable also to a transitory condition then a r...

Page 9: ...el 7 IMPORTANT WARNINGS 1 The appliance only can be used for the purpose that it is destined for 2 The appliance can only be operated by adult persons and children without being supervised by adults must not be left nearby the appliance 3 The appliance is not destined for the use by persons incl children whose physical sensual or mental disability or lack of experience and knowledge prevent them f...

Page 10: ... single usage and no longer can be used as a product Its disposal is subject to Act 477 2001 Sb a 185 2001 Coll as amended In case that the product has lost its serviceability you can take advantage of product take back service if this is established in case that the originator has declared that it is a scrap it must be handled according to the valid legislation of relevant country 10 Guarantee an...

Page 11: ... unit EN 13429 2000 NO 3 1 Recovery by material recycling ensure recyclability in all term sof the standard for the functional packaging unit EN 13430 2000 YES 3 2 Recovery in the form of energy ensure that calorific gain is achievable for the functional packaging unit EN 13431 2000 YES Iron NO 3 3 Recovery by composting ensure compost ability in all terms of the standard for the functional packag...

Page 12: ...12 ...

Page 13: ...g systems in buildings protecting device VIADRUS a s provides the guarantee during 24 months after the date when product was sold the end user The heater will be installed by a contractual service organization The completeness according to Manual for operation and installation is guaranteed by the contractual service organization The guarantee certificate is invalid without having been filled in T...

Page 14: ...e certificate for customer the user Record of accomplished guarantee and after guarantee repairs and regular product checks Record date Carried out activity Contracting service organization stamp signature Customer s signature ...

Page 15: ...830 Heating systems in buildings protecting device VIADRUS a s provides the guarantee during 24 months after the date when product was sold the end user The heater will be installed by a contractual service organization The completeness according to Manual for operation and installation is guaranteed by the contractual service organization The guarantee certificate is invalid without having been f...

Page 16: ...16 ...

Page 17: ...ating systems in buildings protecting device VIADRUS a s provides the guarantee during 24 months after the date when product was sold the end user The heater will be installed by a contractual service organization The completeness according to Manual for operation and installation is guaranteed by the contractual service organization The guarantee certificate is invalid without having been filled ...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...20 Date of revision 46 2012 ND GB ...

Reviews: