COMPRESSOR WIRING DIAGRAM

15 Edelman

Irvine, CA 92618

949-585-0011

www.viaircorp.com

87

86

30

85

+

-

Battery

To Keyed

Power Source

12V  40A

Relay

Fuse

Pressure

Switch

Rev.1

WIRE GAUGE GUIDE 12-VOLT:

Amp Draw

Length of wire from battery to compressor

10

15

20

25

30

10

14

12

10

10

10

15

12

10

10

8

8

20

10

10

8

6

6

25

10

8

6

6

6

30

10

8

6

6

4

40

8

6

6

4

4

50

6

6

4

4

2

60

6

4

4

2

2

LIMITED WARRANTY:

VIAIR Corporation warrants this product, when properly installed and under normal conditions of use, to be 

free from defects in workmanship and materials for a period of one year from its original date of purchase. 

To receive warranty service or repair, please contact VIAIR Corporation.  

Returns should be made within one year of the date of purchase, after a Return Goods Authorization 

(RGA) number has been assigned by VIAIR Corporation.  To obtain RGA, fax a copy of your receipt to 

(949) 585-0188. For complete warranty details, please visit: 

www.viaircorp.com/warranty

PLEASE NOTE:

THIS WARRANTY COVERS PRODUCT DEFECTS ONLY; IT DOES NOT COVER INCIDENTAL 

OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE. 

15 EDELMAN • IRVINE, CA 92618

TEL: (949) 585-0011 • FAX: (949) 585-0188

www.viaircorp.com 

Wiring Diagram:

(Figure 3)

Summary of Contents for 10002

Page 1: ...TEM PART NO 10002 IMPORTANT It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL ...

Page 2: ...your vehicle Please follow these instructions to install your new system OBA Components 1 2 0 Gallon 5 port VIAIR Air Tank 1 275C model VIAIR compressor with leader hose and check valve Check to make sure that you have six labeled packages in your kit Each package contains the parts needed for specific areas of installation and may contain smaller bags within each package for specific uses PARTS P...

Page 3: ... YOU HAVE INSTALLED ALL NECESSARY PORT FITTINGS AND ACCESSORIES Apply sealant to threads of fittings prior to assembly and tighten each part with a wrench Do not over tighten if your port fittings are made from brass since brass threads can be stripped Always release air from tank before servicing WARNING FAILURE TO DRAIN TANK AND REMOVE CONDENSATION WILL CAUSE TANK TO RUST PREMATURELY To remove a...

Page 4: ...lon tape is not recommended Properly sealed recommended torque is 12 to 15 ft lbs 275C Compressor Wiring See Figure 3 on back of manual 1 Disconnect ground cable from vehicle s battery 2 Temporarily position the air compressor in the location where it will be mounted 3 Route ground wire to the negative post of the battery or to an appropriate grounding point and cut ground wire to length as needed...

Page 5: ...onnections Clean and tighten as needed 2 Periodically check all mounting screws Tighten as needed 3 Replace air filter element periodically Replacement frequency depends on operating frequency and operating environment For frequent use in dusty environment you should replace air filter element more often 4 Regularly clean dust and dirt from compressor 5 Your air compressor is equipped with permane...

Page 6: ...es heat sources and tight bends Air line must be routed at least 12 inches from exhaust systems other heat sources IMPORTANT Drilling through firewall Always be sure of what is on the other side of the firewall before drilling Take care not to damage your vehicle s electronic systems or components Wiring an ON OFF Switch Using a relay Run a wire to a simple two position switch that can be mounted ...

Page 7: ... tank to drain Drain tank more frequently 2 Move compressor to area with less humidity or use air line filter Compressor will not run 1 No power or power switch in OFF position 2 Blown fuse 3 Motor overheats 4 Faulty pressure switch 1 Make sure compressor switch is ON 2 Disconnect compressors from power source replace fuse Refer to Specifications section for correct fuse amperage 3 Let compressors...

Page 8: ...ormal conditions of use to be free from defects in workmanship and materials for a period of one year from its original date of purchase To receive warranty service or repair please contact VIAIR Corporation Returns should be made within one year of the date of purchase after a Return Goods Authorization RGA number has been assigned by VIAIR Corporation To obtain RGA fax a copy of your receipt to ...

Reviews: