background image

USER MANUAL

150C-IG COMPRESSOR KIT

COMPRESSOR APPLICATION GUIDE

To ensure that you get the highest level of satisfaction from your compressor’s performance, refer to 

information below: 

VIAIR COMPRESSOR REFERENCE CHART

COMPRESSOR SERIES 

MAX. WORKING 

DUTY CYCLE

 

PRESSURE  

(100 PSI @ 72°F)

090 SERIES 

120 PSI  

9%  

 

092 SERIES 

120 PSI  

9%  

095 SERIES 

120 PSI  

9%  

097 SERIES 

130 PSI  

10%  

098 SERIES 

130 PSI  

10%  

100 SERIES 

130 PSI  

15% 

150 SERIES 

150 PSI  

25%  

250 IG SERIES 

150 PSI  

100%  

275 SERIES 

150 PSI  

25%  

280 SERIES 

150 PSI  

30%  

325 SERIES 

150 PSI  

33%  

330 IG SERIES 

150 PSI  

100%  

350 SERIES 

150 PSI  

100%  

380 SERIES 

200 PSI  

100%  

 

 

 

55% @ 200 PSI

400 SERIES 

150 PSI  

33%  

420 SERIES 

150 PSI  

33%  

425 SERIES 

175 PSI 

 33% @ 175 PSI 

 

 

 

50%

444 SERIES 

200 PSI  

100%  

 

 

 

50% @ 200 PSI

450 SERIES 

150 PSI  

100%  

450 IG SERIES 

150 PSI  

100%  

460 SERIES 

150 PSI  

100%  

480 SERIES 

200 PSI  

100%  

 

 

 

50% @ 200 PSI

485 SERIES 

200 PSI  

100%  

 

 

 

100% @ 200 PSI

ABOUT COMPRESSOR DUTY CYCLE:

Duty cycle refers to the amount of time a compressor can be
operated in a given time period at 100 

PSI, and a standard ambient temperature of 72° F. It is commonly expressed in percentage format: 

Compressor on time ÷ (on time + off time) = Duty Cycle %.

ONE-HOUR DUTY CYCLE   

MINUTES ON / 

(100 PSI @ 72°F) 

  MINUTES 

OFF

  9% 

5 Min. On / 55 Min. Off

  10% 

6 Min. On / 54 Min. Off

  15% 

9 Min. On / 51 Min. Off

  20% 

12 Min. On / 48 Min. Off

  25% 

15 Min. On / 45 Min. Off 

  30% 

18 Min. On / 42 Min. Off

  33% 

20 Min. On / 40 Min. Off

  50% 

30 Min. On / 30 Min. Off

 100%  

    1 Hour Run Time

NOTE: All compressors, regardless of rated duty cycle, require sufficient rest time in between cycles 

to allow for partial or complete heat dissipation. Heat dissipation rates may vary depending on 

ambient temperatures and operating conditions.

ABOUT RATED WORKING PRESSURE:

To ensure trouble free service life of your compressor, always operate compressor within rated 

working pressure of the compressor. Never use a pressure switch with a higher cut-off pressure than 

Summary of Contents for 150C-IG

Page 1: ......

Page 2: ... damage to the compressor and your vehicle Each air compressor has been carefully produced and packaged Before installation please familiarize yourself with Installation Parts List Fig 1 of this manual Guidelines for Selecting Mounting Location The selection of proper mounting location for your air compressor will help ensure a long and trouble free compressor service life Please note the followin...

Page 3: ...r pressure switch The use of a relay is recommended Refer to the Recommended wiring diagram in Fig 4 10 Make sure that your compressor setup is properly fused For appropriate fuse size refer to amp draw of compressor in the specifications section of this manual 11 Always locate fuse as close as possible to power source 12 Before connecting to power source re check to make sure that all connections...

Page 4: ... 5 To prevent discharge of your vehicle s battery and enhance performance keep the vehicle s engine running while using the compressor 6 Only operate compressor in well ventilated areas 7 The use of a relay is strongly recommended for installation of this compressor 40 Amp relay value or higher MAINTENANCE REPAIRS 1 Periodically check all electrical and fittings connections Clean and tighten as ne...

Page 5: ...t Magnetic Horsepower 1 4 Max Working Pressure 150 PSI Max Duty Cycle 72 F 100 PSI 25 Minutes On Off 72 F 100 PSI 15 min 45 min Max Restart Pressure 150 PSI Max Ambient Temperature 158 F Min Ambient Temperature 40 F Auto Reset Thermal Protection Yes Ingress Protection Rating IP67 Dimensions 6 89 L x 3 27 W x 4 97H Net Weight 4 1 Lbs USER MANUAL 150C IG COMPRESSOR KIT ...

Page 6: ...85 SERIES 200 PSI 100 100 200 PSI ABOUT COMPRESSOR DUTY CYCLE Duty cycle refers to the amount of time a compressor can beoperated in a given time period at 100 PSI and a standard ambient temperature of 72 F It is commonly expressed in percentage format Compressor on time on time off time Duty Cycle ONE HOUR DUTY CYCLE MINUTES ON 100 PSI 72 F MINUTES OFF 9 5 Min On 55 Min Off 10 6 Min On 54 Min Off...

Page 7: ...in tank more frequently 2 Move compressor to area with less humidity or use air line filter Compressor will not run 1 No power or power switch in OFF position 2 Blown fuse 3 Motor overheats 4 Faulty pressure switch 1 Make sure compressor switch is ON 2 Disconnect compressors from power source replace fuse Refer to Specifications section for correct fuse amperage 3 Let compressors cool off for abou...

Page 8: ...ed as to the accuracy or completeness of the Manual Users must be aware that updates and amendments will be made from time to time to the Manual It is the user s responsibility to determine whether there have been any such updates or amendments Neither VIAIR nor any of its directors officers employees or agents shall be liable in contract tort or in any other manner whatsoever to any person for an...