USER MANUAL

250C-IG COMPRESSOR KIT

COMPRESSOR APPLICATION GUIDE

To ensure that you get the highest level of satisfaction from your compressor’s performance, refer to 

information below: 

VIAIR COMPRESSOR REFERENCE CHART

COMPRESSOR SERIES 

DUTY CYCLE 

MAX. WORKING PRESSURE

 

 

 

(100 PSI @ 72°F)

090 SERIES 

9% 

 

120 PSI

092 SERIES 

9% 

 

120 PSI

095 SERIES 

9% 

 

120 PSI

097 SERIES 

10% 

 

130 PSI

098 SERIES 

10% 

 

130 PSI

100 SERIES 

15% 

 

130 PSI

250 IG SERIES 

100% 

 

150 PSI

275 SERIES 

25% 

 

150 PSI

280 SERIES 

30% 

 

150 PSI

325 SERIES 

33% 

 

150 PSI

330 IG SERIES 

100% 

 

150 PSI

350 SERIES 

100% 

 

150 PSI

380 SERIES 

100%      

200 PSI

 

*55%

400 SERIES 

33% 

 

150 PSI

420 SERIES 

33% 

 

150 PSI

444 SERIES 

100%   

 

200 PSI

 

*50%

450 SERIES 

100% 

 

150 PSI

450 IG SERIES 

100% 

 

150 PSI

460 SERIES 

100% 

 

150 PSI

480 SERIES 

100%   

 

200 PSI

 

*50%

*Duty Cycle at 200 PSI and 72°F. 

ABOUT COMPRESSOR DUTY CYCLE:

Duty cycle refers to the amount of time a compressor can be
operated in a given time period at 100 

PSI, and a standard ambient temperature of 72° F. It is commonly expressed in percentage format: 

Compressor on time ÷ (on time + off time) = Duty Cycle %.

ONE-HOUR DUTY CYCLE   

MINUTES ON / 

(100 PSI @ 72°F)

 

  MINUTES 

OFF

  9% 

5 Min. On / 55 Min. Off

  10% 

6 Min. On / 54 Min. Off

  15% 

9 Min. On / 51 Min. Off

  20% 

12 Min. On / 48 Min. Off

  25% 

15 Min. On / 45 Min. Off 

  30% 

18 Min. On / 42 Min. Off

  33% 

20 Min. On / 40 Min. Off

  50% 

30 Min. On / 30 Min. Off

 100%                                                     1 Hour Run Time

NOTE:

 All compressors, regardless of rated duty cycle, require sufficient rest time in between cycles 

to allow for partial or complete heat dissipation. Heat dissipation rates may vary depending on 

ambient temperatures and operating conditions.

ABOUT RATED WORKING PRESSURE:

To ensure trouble free service life of your compressor, always operate compressor within rated 

working pressure of the compressor. Never use a pressure switch with a higher cut-off pressure than 

compressor’s rated working pressure. 

Summary of Contents for 250C-IG

Page 1: ...IG COMPRESSOR KIT 24V PART NO 25058 IMPORTANT It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL ...

Page 2: ...void injury or damage to the compressor and your vehicle Each air compressor has been carefully produced and packaged Before installation please familiarize yourself with Installation Parts List Fig 1 of this manual Guidelines for Selecting Mounting Location The selection of proper mounting location for your air compressor will help ensure a long and trouble free compressor service life Please not...

Page 3: ...ositive lead wire to one of the leads of your pressure switch The use of a relay is recommended Refer to the Recommended wiring diagram in Fig 4 11 Make sure that your compressor setup is properly fused For appropriate fuse size refer to amp draw of compressor in the specifications section of this manual 12 Always locate fuse as close as possible to power source 13 Before connecting to power sourc...

Page 4: ...air compressor 5 To prevent discharge of your vehicle s battery and enhance performance keep the vehicle s engine running while using the compressor 6 Only operate compressor in well ventilated areas 7 The use of a relay is strongly recommended for installation of this compressor MAINTENANCE REPAIRS 1 Periodically check all electrical and fittings connections Clean and tighten as needed 2 Periodic...

Page 5: ...40 F Auto Reset Thermal Protection Yes Dimensions 7 4 L x 3 9 W x 6 75H Net Weight 6 75 Lbs Part No 25058 250C IG 24V Compressor Kit CE Spec Motor Voltage 24 Volts Max Current Consumption 6 Amps Recommended Fuse 10 Amps Motor Type Permanent Magnetic Horsepower 1 4 Max Working Pressure 150 PSI Max Duty Cycle 72 F 100 PSI 100 Minutes On Off 72 F 100 PSI Continuous Max Restart Pressure 150 PSI Max Am...

Page 6: ...E Duty cycle refers to the amount of time a compressor can beoperated in a given time period at 100 PSI and a standard ambient temperature of 72 F It is commonly expressed in percentage format Compressor on time on time off time Duty Cycle ONE HOUR DUTY CYCLE MINUTES ON 100 PSI 72 F MINUTES OFF 9 5 Min On 55 Min Off 10 6 Min On 54 Min Off 15 9 Min On 51 Min Off 20 12 Min On 48 Min Off 25 15 Min On...

Page 7: ...in tank more frequently 2 Move compressor to area with less humidity or use air line filter Compressor will not run 1 No power or power switch in OFF position 2 Blown fuse 3 Motor overheats 4 Faulty pressure switch 1 Make sure compressor switch is ON 2 Disconnect compressors from power source replace fuse Refer to Specifications section for correct fuse amperage 3 Let compressors cool off for abou...

Page 8: ...CTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE 15 EDELMAN IRVINE CA 92618 TEL 949 585 0011 FAX 949 585 0188 www viaircorp com Fig 4 Recommended Wiring Diagram Fuse Not Included SINGLE C MODEL COMPRESSOR WIRING DIAGRAM 15 Edelman Irvine CA 92618 949 585 0011 www viaircorp com 87 86 30 85 Battery To Keyed Power Source 40A Relay Fuse Pressure Switch Rev 1 ...

Reviews: