Summary of Contents for 330C-HG

Page 1: ......

Page 2: ... carefully to avoid injury or damage to the compressor and your vehicle Each air compressor has been carefully produced and packaged Before installation please familiarize yourself with Installation Parts List Fig 1 of this manual Guidelines for Selecting Mounting Location The selection of proper mounting location for your air compressor will help ensure a long and trouble free compressor service ...

Page 3: ...our pressure switch 10 Make sure that your compressor setup is properly fused For appropriate fuse size refer to amp draw of compressor in the specifications section of this manual 11 Always locate fuse as close as possible to power source 12 Before connecting to power source re check to make sure that all connections are made properly 13 Connect and test compressor system by running the compresso...

Page 4: ...d for installation of this compressor 40 amp relay value or higher MAINTENANCE REPAIRS 1 Periodically check all electrical and fittings connections Clean and tighten as needed 2 Periodically check all mounting screws Tighten as needed 3 Replace air filter element periodically Replacement frequency depends on operating frequency and operating environment For frequent use in dusty environment we rec...

Page 5: ...USER MANUAL 330C HG 200PSI COMPRESSOR KIT ...

Page 6: ...85 SERIES 200 PSI 100 100 200 PSI ABOUT COMPRESSOR DUTY CYCLE Duty cycle refers to the amount of time a compressor can beoperated in a given time period at 100 PSI and a standard ambient temperature of 72 F It is commonly expressed in percentage format Compressor on time on time off time Duty Cycle ONE HOUR DUTY CYCLE MINUTES ON 100 PSI 72 F MINUTES OFF 9 5 Min On 55 Min Off 10 6 Min On 54 Min Off...

Page 7: ...ank more frequently 2 Move compressor to area with less humidity or use air line filter Compressor will not run 1 No power or power switch in OFF position 2 Blown fuse 3 Motor overheats 4 Faulty pressure switch 1 Make sure compressor switch is ON 2 Disconnect compressors from power source replace fuse Refer to Specifications section for correct fuse amperage 3 Let compressors cool off for about 30...

Page 8: ...eceipt to 949 585 0188 For complete warranty details please visit www viaircorp com warranty PLEASE NOTE THIS WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE This Manual is proprietary to VIAIR Corporation and no ownership rights are hereby transferred No part of the Manual shall be used reproduced translated converted adapted...