background image

OPERATING INSTRUCTIONS

 

1.  IMPORTANT: Always operate the compressor at or below the MAXIMUM PRESSURE RATING of 

   the compressor. Please refer to Application & Specifications Sections of this manual for details.

2.  Always observe the MAXIMUM DUTY CYCLE of the air compressor. Refer to Compressor 

   Applications and Specifications Sections of this manual for details. Operation exceeding 

   maximum pressure ratings and/or duty cycle will result in damage to the air compressor. 

3.  Your air compressor is equipped with an AUTOMATIC THERMAL OVERLOAD PROTECTOR. 

  This feature is designed to protect the air compressor from overheating and causing permanent 

   damage to your air compressor. The thermal overload protector will automatically cut power to 

   your air compressor should the internal operating temperature of the air compressor rise above 

   safe levels during excessive use. 

4.  Should at any time during use, your air compressor automatically shuts off; do not attempt to 

   restart the air compressor. Turn off power and allow unit to cool for about 30 minutes. This will 

   allow the Thermal Overload Protector to reset so you can safely resume use of the air compressor.

5. To prevent discharge of battery (power source), always supply charging voltage to enhance

  performance. (12-volt charging voltage up to 13.8 volts). 

6.  Only operate compressor in well ventilated areas. 

7. The use of a relay is strongly recommended for installation of this compressor.  

  (40-amp relay value or higher).

MAINTENANCE & REPAIRS

1.  Periodically check all electrical and fittings connections. Clean and tighten as needed. 

2.  Periodically check all mounting screws. Tighten as needed.

3.  Replace air filter element periodically. Replacement frequency depends on operating frequency and 

   operating environment. For frequent use in dusty environment, we recommend that you replace air 

   filter element at least once a month. 

4.  Regularly clean dust and dirt from compressor cooling fins and motor housing.

5.  Your air compressor is equipped with a permanently lubricated, maintenance free motor. 

  Never try to lubricate the compressor.

6.  All repairs should be performed by Manufacturer or Manufacturer’s Authorized Service Agent only. 

 

CAUTION: 

Never touch the air compressor or fittings connected to the air compressor with bare hands during 

or immediately after use. The leader hose and fittings connected to leader hose will become very 

HOT during and after use. If necessary, wear heat resistant gloves to handle fittings, air line, and 

leader hose. 

SPECIFICATIONS

• Part No. 33035 / 330C-HG-200PSI 12V Compressor Kit 

(CE Spec.)

Motor Voltage: 

 

 

12 Volts 

Max. Current Consumption:    

14 Amps

Recommended Fuse: 

 

20 Amps

Motor Type: 

 

 

Permanent Magnetic

Horsepower: 

 

 

1/4

Max. Working Pressure: 

 

200 PSI

Max. Duty Cycle (@ 72°F & 100 PSI):  100%

Minutes On/Off (@ 72°F & 200 PSI): 

  50%

Max. Restart Pressure: 

 

200 PSI

Max. Ambient Temperature:   

158°F

Min. Ambient Temperature:   

-40°F  

Auto. Reset Thermal Protection: 

Yes

Dimensions: 

9"L x 4"W x 6.75H"

Net Weight: 

8.25 Lbs.

USER MANUAL

330C-HG - 200PSI COMPRESSOR KIT

Summary of Contents for 330C-HG

Page 1: ......

Page 2: ... carefully to avoid injury or damage to the compressor and your vehicle Each air compressor has been carefully produced and packaged Before installation please familiarize yourself with Installation Parts List Fig 1 of this manual Guidelines for Selecting Mounting Location The selection of proper mounting location for your air compressor will help ensure a long and trouble free compressor service ...

Page 3: ...our pressure switch 10 Make sure that your compressor setup is properly fused For appropriate fuse size refer to amp draw of compressor in the specifications section of this manual 11 Always locate fuse as close as possible to power source 12 Before connecting to power source re check to make sure that all connections are made properly 13 Connect and test compressor system by running the compresso...

Page 4: ...d for installation of this compressor 40 amp relay value or higher MAINTENANCE REPAIRS 1 Periodically check all electrical and fittings connections Clean and tighten as needed 2 Periodically check all mounting screws Tighten as needed 3 Replace air filter element periodically Replacement frequency depends on operating frequency and operating environment For frequent use in dusty environment we rec...

Page 5: ...USER MANUAL 330C HG 200PSI COMPRESSOR KIT ...

Page 6: ...85 SERIES 200 PSI 100 100 200 PSI ABOUT COMPRESSOR DUTY CYCLE Duty cycle refers to the amount of time a compressor can beoperated in a given time period at 100 PSI and a standard ambient temperature of 72 F It is commonly expressed in percentage format Compressor on time on time off time Duty Cycle ONE HOUR DUTY CYCLE MINUTES ON 100 PSI 72 F MINUTES OFF 9 5 Min On 55 Min Off 10 6 Min On 54 Min Off...

Page 7: ...ank more frequently 2 Move compressor to area with less humidity or use air line filter Compressor will not run 1 No power or power switch in OFF position 2 Blown fuse 3 Motor overheats 4 Faulty pressure switch 1 Make sure compressor switch is ON 2 Disconnect compressors from power source replace fuse Refer to Specifications section for correct fuse amperage 3 Let compressors cool off for about 30...

Page 8: ...eceipt to 949 585 0188 For complete warranty details please visit www viaircorp com warranty PLEASE NOTE THIS WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE This Manual is proprietary to VIAIR Corporation and no ownership rights are hereby transferred No part of the Manual shall be used reproduced translated converted adapted...

Reviews: