background image

OPERATING INSTRUCTIONS

  

1.  IMPORTANT: Always operate the compressor at or below the MAXIMUM PRESSURE RATING of 

     the compressor.  Please refer to Application & Specifications Sections of this manual for details.

2.  Always observe the MAXIMUM DUTY CYCLE of the air compressor.  Refer to Compressor 

     Applications and Specifications Sections of this manual for details. Operation exceeding 

     maximum pressure ratings and/or duty cycle will result in damage to the air compressor.  

3.  Your air compressor is equipped with an AUTOMATIC THERMAL OVERLOAD PROTECTOR.  

  This feature is designed to protect the air compressor from overheating and causing permanent 

     damage to your air compressor. The thermal overload protector will automatically cut power to 

     your air compressor should the internal operating temperature of the air compressor rise above 

     safe levels during excessive use. 

4.  Should at any time during use, your air compressor automatically shuts off; do not attempt to 

     restart the air compressor.  Turn off power and allow unit to cool for about 30 minutes. This will 

     allow the Thermal Overload Protector to reset so you can safely resume use of the air compressor.

5. To prevent discharge of battery (power source), always supply charging voltage to enhance

  performance. (12-volt charging voltage up to 14.4 volts & 24-volt charging voltage up to 28 volts). 

6.  Only operate compressor in well ventilated areas. 

7. The use of a relay is strongly recommended for installation of this compressor.  

  (60-amp relay value or higher).

MAINTENANCE & REPAIRS

1.  Periodically check all electrical and fittings connections.  Clean and tighten as needed.  

2.  Periodically check all mounting screws.  Tighten as needed.

3.  Replace air filter element periodically. Replacement frequency depends on operating frequency and 

     operating environment.  For frequent use in dusty environment, we recommend that you replace air 

     filter element at least once a month.  

4.  Regularly clean dust and dirt from compressor cooling fins and motor housing.

5.  Your air compressor is equipped with a permanently lubricated, maintenance free motor. 

  Never try to lubricate the compressor.

6.  All repairs should be performed by Manufacturer or Manufacturer’s Authorized Service Agent only.  

 

CAUTION: 

Never touch the air compressor or fittings connected to the air compressor with bare hands during 

or immediately after use. The leader hose and fittings connected to leader hose will become very 

HOT during and after use. If necessary, wear heat resistant gloves to handle fittings, air line, and 

leader hose. 

SPECIFICATIONS

• Part No.  33050 / 330C-IG-12V Compressor Kit 

(CE Spec.)

Motor Voltage: 

 

 

12 Volts 

Max. Current Consumption:    

12 Amps

Motor Type: 

 

 

Permanent Magnetic

Horsepower: 

 

 

1/4

Max. Working Pressure: 

 

150 PSI

Max. Duty Cycle (@ 72°F & 100 PSI): 

100%

Minutes On/Off (@ 72°F & 100 PSI): 

Continuous

Max. Restart Pressure: 

 

200 PSI

Max. Ambient Temperature:   

158°F

Min. Ambient Temperature:   

-40°F  

Auto. Reset Thermal Protection: 

Yes

Dimensions: 

8.86”L x 4”W x 6.75H”

Net Weight: 

8.25 Lbs.

USER MANUAL

330C-IG - 450C-IG COMPRESSOR KIT 

Summary of Contents for 330C-IG

Page 1: ...he contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL 330C IG COMPRESSOR KIT 12V PART NO 33050 330C IG COMPRESSOR KIT 24V PART NO 33058 450C IG COMPRESSOR KIT 12V PART NO 45050 450C IG COMPRESSOR KIT 24V PART NO 45058 330C IG 450C IG ...

Page 2: ...ctions carefully to avoid injury or damage to the compressor or your vehicle Each air compressor has been carefully produced and packaged Before installation please familiarize yourself with Installation Parts List Fig 1 of this manual Guidelines for Selecting Mounting Location The selection of proper mounting location for your air compressor will help ensure a long and trouble free compressor ser...

Page 3: ...10 Connect compressor s positive lead wire to one of the leads of your pressure switch 11 Make sure that your compressor setup is properly fused For appropriate fuse size refer to amp draw of compressor in the specifications section of this manual 12 Always locate fuse as close as possible to power source 13 Before connecting to power source re check to make sure that all connections are made prop...

Page 4: ...a relay is strongly recommended for installation of this compressor 60 amp relay value or higher MAINTENANCE REPAIRS 1 Periodically check all electrical and fittings connections Clean and tighten as needed 2 Periodically check all mounting screws Tighten as needed 3 Replace air filter element periodically Replacement frequency depends on operating frequency and operating environment For frequent u...

Page 5: ...ic Horsepower 1 4 Max Working Pressure 150 PSI Max Duty Cycle 72 F 100 PSI 100 Minutes On Off 72 F 100 PSI Continuous Max Restart Pressure 200 PSI Max Ambient Temperature 158 F Min Ambient Temperature 40 F Auto Reset Thermal Protection Yes Dimensions 10 L x 4 W x 6 75H Net Weight 10 40 Lbs Part No 45058 450C IG 24V Compressor Kit CE Spec Motor Voltage 24 Volts Max Current Consumption 11 Amps Motor...

Page 6: ...ture of 72 F Duty Cycle is commonly expressed in percentile as Compressor on Time Compressor on Time Off Time As an example a compressor that is rated for 25 duty cycle means that compressor can be operated at 100 PSI 72 F for 10 Minutes ON and 30 Minutes OFF 10 Min On 10 Min On 30 Min Off 10 Min 40 Min 25 Duty Cycle DUTY CYCLE REFERENCE CHART DUTY CYCLE 100PSI 72 F MINUTES ON OFF 15 6 Min On 34 M...

Page 7: ...ank more frequently 2 Move compressor to area with less humidity or use air line filter Compressor will not run 1 No power or power switch in OFF position 2 Blown fuse 3 Motor overheats 4 Faulty pressure switch 1 Make sure compressor switch is ON 2 Disconnect compressors from power source replace fuse Refer to Specifications section for correct fuse amperage 3 Let compressors cool off for about 30...

Page 8: ... of purchase after a Return Goods Authorization RGA number has been assigned by VIAIR Corporation To obtain an RGA number fax a copy of your receipt to 949 585 0188 For complete warranty details visit www viaircorp com warranty IMPORTANT THIS WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE VIAIR CORPORATION 15 EDELMAN IRVINE C...