TROUBLESHOOTING GUIDE:

Tank pressure drops when 
compressor (s) shut off

1. Loose drain cock
2. Check valve leaking
3. Loose connections

1. Tighten drain cock
2. Replace check valve or

  compressor(s)

3. Check all connections with

 soap and water solution 
 and tighten

Compressor runs 
continuously and air flow 
lower than normal

1. Excessive air usage
2. Loose connections
3. Worn piston ring or inlet

  valve.

4. Clogged air filter element 

1. Decrease air usage
2. Check all connections with

 soap and water solution 
 and tighten.

3. Repair or replace compressor
4. Replace air filter element 

Compressor runs 
continuously causing 
safety valve (if equipped) 
to open

1. Bad pressure switch
2. Defective safety valve

1. Replace pressure switch
2. Replace safety valve

Excessive moisture 
in discharge

1. Excessive water in air tank
2. High humidity

1. Drain tank, tilt tank to drain.

 Drain tank more frequently

2. Move compressor to area

 with less humidity, or use air 
 line filter.

Compressor will not run

1. No power, or  power switch

  in OFF position

2. Blown fuse
3. Motor overheats
4. Faulty pressure switch. 

1. Make sure compressor

 switch is ON   

2. Disconnect compressors

 from power source, replace 
 fuse.  (Refer to Specifications 
 section for correct fuse 
 amperage.)

3. Let compressors cool off for

 about 30 Minutes to allow 
 thermal overload switch reset.

4. Replace pressure switch

Thermal overload 
protector cuts 
out repeatedly

1. Lack of proper ventilation or

 ambient temperature too high

2. Compressor valves failed

1. Move compressor to well

 ventilated area, or area with 
 lower ambient temperature

2. Repair or replace compressor

Excessive knocking 
or rattling

1. Loose mounting bolts
2. Worn bearing on eccentric or

 motor shaft

3. Cylinder or piston ring is worn

1. Tighten mounting bolts
2. Repair or replace compressor
3. Repair or replace compressor 

CAUTION:  NEVER DISASSEMBLE COMPRESSOR WHILE 

COMPRESSOR IS PRESSURIZED.

USER MANUAL

330C-IG - 450C-IG COMPRESSOR KIT 

Summary of Contents for 330C-IG

Page 1: ...he contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL 330C IG COMPRESSOR KIT 12V PART NO 33050 330C IG COMPRESSOR KIT 24V PART NO 33058 450C IG COMPRESSOR KIT 12V PART NO 45050 450C IG COMPRESSOR KIT 24V PART NO 45058 330C IG 450C IG ...

Page 2: ...ctions carefully to avoid injury or damage to the compressor or your vehicle Each air compressor has been carefully produced and packaged Before installation please familiarize yourself with Installation Parts List Fig 1 of this manual Guidelines for Selecting Mounting Location The selection of proper mounting location for your air compressor will help ensure a long and trouble free compressor ser...

Page 3: ...10 Connect compressor s positive lead wire to one of the leads of your pressure switch 11 Make sure that your compressor setup is properly fused For appropriate fuse size refer to amp draw of compressor in the specifications section of this manual 12 Always locate fuse as close as possible to power source 13 Before connecting to power source re check to make sure that all connections are made prop...

Page 4: ...a relay is strongly recommended for installation of this compressor 60 amp relay value or higher MAINTENANCE REPAIRS 1 Periodically check all electrical and fittings connections Clean and tighten as needed 2 Periodically check all mounting screws Tighten as needed 3 Replace air filter element periodically Replacement frequency depends on operating frequency and operating environment For frequent u...

Page 5: ...ic Horsepower 1 4 Max Working Pressure 150 PSI Max Duty Cycle 72 F 100 PSI 100 Minutes On Off 72 F 100 PSI Continuous Max Restart Pressure 200 PSI Max Ambient Temperature 158 F Min Ambient Temperature 40 F Auto Reset Thermal Protection Yes Dimensions 10 L x 4 W x 6 75H Net Weight 10 40 Lbs Part No 45058 450C IG 24V Compressor Kit CE Spec Motor Voltage 24 Volts Max Current Consumption 11 Amps Motor...

Page 6: ...ture of 72 F Duty Cycle is commonly expressed in percentile as Compressor on Time Compressor on Time Off Time As an example a compressor that is rated for 25 duty cycle means that compressor can be operated at 100 PSI 72 F for 10 Minutes ON and 30 Minutes OFF 10 Min On 10 Min On 30 Min Off 10 Min 40 Min 25 Duty Cycle DUTY CYCLE REFERENCE CHART DUTY CYCLE 100PSI 72 F MINUTES ON OFF 15 6 Min On 34 M...

Page 7: ...ank more frequently 2 Move compressor to area with less humidity or use air line filter Compressor will not run 1 No power or power switch in OFF position 2 Blown fuse 3 Motor overheats 4 Faulty pressure switch 1 Make sure compressor switch is ON 2 Disconnect compressors from power source replace fuse Refer to Specifications section for correct fuse amperage 3 Let compressors cool off for about 30...

Page 8: ... of purchase after a Return Goods Authorization RGA number has been assigned by VIAIR Corporation To obtain an RGA number fax a copy of your receipt to 949 585 0188 For complete warranty details visit www viaircorp com warranty IMPORTANT THIS WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE VIAIR CORPORATION 15 EDELMAN IRVINE C...

Reviews: