background image

IMPORTANT SAFETY INSTRUCTIONS

CAUTION - To reduce risk of electrical shock or electrocution:

-  Do not disassemble.  Do not attempt repairs or modifications.  Refer to qualified service agencies  

  for all service and repairs.

-  Do not use this product in or area where it can fall or be pulled into water or other liquids.

-  Do not reach for this product if it has fallen into liquid. 

-  Use this compressor with 12-volt DC systems only.

-  This product should never be left unattended during use.

WARNING - To prevent injury:

-  Never allow children to operate this compressor.  Close supervision is necessary when this compressor  

  is being used near children.

-  This compressor will become very HOT during and immediately after use.  Do not touch any part of this  

  compressor with bare hands, during and immediately after use. 

-  Do not use this product near flames or explosive materials or where aerosol products are being used.

-  Do not operate this product where oxygen is being administered. 

-  Do not pump anything other than atmospheric air.

-  Never use this product while sleepy or drowsy.

-  Do not use any tools or attachments without first determining maximum air pressure for that tool 

  or attachment.

-  Never point any air nozzle or air sprayer toward another person or any part of the body.

-  This air compressor is equipped with an Automatic Reset Thermal Protector, and can automatically  

  restart after the thermal protector resets.  Always cut off power source when thermal protector 

  becomes activated.  

-  Wear safety glasses or goggles when operating this product.

-  Use only in well ventilated areas.

INSTALLATION

Please read and follow the Installation Instructions carefully to avoid injury or damage to the 

compressor or your vehicle.

Each of our air compressors and parts have been carefully produced and packaged.  Before 

installation, please familiarize yourself with Installation Parts List (Fig. 1) of this manual.  

Guidelines for Selecting Mounting Location:

The selection of proper mounting location for your air compressor will help ensure a long and 

trouble free compressor service life. Please pay close attention to the following guidelines: 

1. Select a FLAT, UPRIGHT AND SECURE location where the compressor can be mounted.

2. To maximize air compressor performance, locate compressor as CLOSE TO THE BATTERY as  

  possible so that length of positive lead wire required is at a minimum.  

3. Choose mounting location that is as cool as possible and AWAY FROM HEAT SOURCES. 

  The cooler the ambient temperature, the less chance the compressor will overheat. 

4. This compressor is moisture & splash resistant, but NOT WATERPROOF. Do not mount    

  compressor in locations where the unit is likely to come in contact with water. 

5. For remote filter mounting, select compressor’s mounting location where air line can be routed  

  from compressor air inlet to remote inlet air filter.  Make sure Remote Inlet Air Filter is located in a  

  dry location, away from the elements.  

6. You will also want to select compressor mounting location where the leader hose bracket can be  

  mounted to secure the leader hose. 

7. If it is necessary to mount the air compressor further away from the battery, such as inside  

  your vehicle or in the bed of your pickup, use a minimum 8 AWG positive lead wire for 

  remote installation.

8. Do not mount compressor near areas where flammable liquids are stored.

9. Use thread sealant for proper fitting installation. Teflon tape is not recommended. 

  Properly sealed, recommended torque is 12 to 15 ft. lbs

USER MANUAL

380C - 480C COMPRESSOR KIT 

Summary of Contents for 380C

Page 1: ...T NO 48043 200 PSI COMPRESSORS MODEL NUMBERS IMPORTANT It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL 380C 480C ...

Page 2: ... injury or damage to the compressor or your vehicle Each of our air compressors and parts have been carefully produced and packaged Before installation please familiarize yourself with Installation Parts List Fig 1 of this manual Guidelines for Selecting Mounting Location The selection of proper mounting location for your air compressor will help ensure a long and trouble free compressor service l...

Page 3: ...et and secure hose by pressing bracket clamp into locked position 10 To remove hose from the hose bracket simply press down on the hose clamp release tab to release bracket clamp Fig 3 11 Connect compressor s positive lead wire to one of the leads of your pressure switch 12 Make sure that your compressor setup is properly fused For appropriate fuse size refer to amp draw of compressor in the speci...

Page 4: ...e s engine running while using the air compressor 6 ONLY OPERATE THE AIR COMPRESSOR IN WELL VENTILATED AREAS 7 Compressor performance is enhanced when operating compressor with vehicle s engine running MAINTENANCE REPAIRS 1 Periodically check all electrical fittings connections Clean and tighten as needed 2 Periodically check all mounting screws Tighten as needed 3 Replace Air Filter Element perio...

Page 5: ...0ºF Auto Reset Thermal Protection Yes Dimensions 9 L x 4 W x 6 75 H Net Weight 8 75 Lbs Part No 48043 480C Air Compressor CE Spec Motor Voltage 12 Volts Max Current Consumption 20 Amps Motor Type Permanent Magnetic Horsepower 1 4 Max Working Pressure 200 PSI Max Duty Cycle 72ºF 100 200 PSI 100 50 Minutes On Off 72ºF 100 PSI Continuous Max Ambient Temperature 158ºF Min Ambient Temperature 58ºF Auto...

Page 6: ... Off Time As an example a compressor that is rated for 25 duty cycle means that compressor can be operated at 100 PSI 72 F for 10 Minutes ON and 30 Minutes OFF 10 Min On 10 Min On 30 Min Off 10 Min 40 Min 25 Duty Cycle DUTY CYCLE REFERENCE CHART DUTY CYCLE 100PSI 720 F MINUTES ON OFF 15 6 Min On 34 Min Off 20 8 Min On 32 Min Off 25 10 Min On 30 Min Off 30 13 Min On 30 Min Off 33 15 Min On 30 Min O...

Page 7: ...equently 2 Move compressor to area with less humidity or use air line filter Compressor will not run 1 No power or power switch in OFF position 2 Blown fuse 3 Motor overheats 4 Faulty pressure switch if hooked up to a pressure switch 1 Make sure compressor switch is ON 2 Disconnect compressor from power source replace fuse Refer to Specifications section for correct fuse amperage 3 Let compressor ...

Page 8: ... purchase after a Return Goods Authorization RGA number has been assigned by VIAIR Corporation To obtain an RGA number fax a copy of your receipt to 949 585 0188 For complete warranty details visit www viaircorp com warranty IMPORTANT THIS WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE VIAIR CORPORATION 15 EDELMAN IRVINE CA 9...