COMPRESSOR APPLICATION GUIDE
To ensure that you get the highest level of satisfaction from your compressor’s performance, refer to
information below:
VIAIR COMPRESSOR REFERENCE CHART
COMPRESSOR SERIES
DUTY CYCLE
WORKING PRESSURE
100 SERIES
15%
130 PSI
200 SERIES
20%
150 PSI
275 SERIES
25%
150 PSI
280 SERIES
30%
150 PSI
325 SERIES
33%
150 PSI
350 SERIES
100%
150 PSI
380 SERIES
100%
200 PSI
400 SERIES
33%
150 PSI
450 SERIES
100%
150 PSI
480 SERIES
100%
200 PSI
ABOUT COMPRESSOR DUTY CYCLE:
Compressor Duty Cycle refers to amount of time a compressor can be operated in a given time
period, at 100 PSI and at a standard ambient temperature of 72°F. Duty Cycle is commonly
expressed in percentile as:
Compressor On Time/ (Compressor On Time + Off Time)%
As an example, a compressor that is rated for 25% duty cycle means that compressor
can be operated at:
100 PSI @ 72°F for 10 Minutes ON and 30 Minutes OFF
10 Min. On / (10 Min. On + 30 Min. Off) = 10 Min. / 40 Min.
=25% Duty Cycle
DUTY CYCLE REFERENCE CHART
DUTY CYCLE @100PSI / 72
0
F
MINUTES ON / OFF
15%
6 Min. On / 34 Min. Off
20%
8 Min. On / 32 Min. Off
25%
10 Min. On / 30 Min. Off
30%
13 Min. On / 30 Min. Off
33%
15 Min. On / 30 Min. Off
100%
Continuous Duty
ABOUT RATED WORKING PRESSURE:
To ensure trouble free service life of your compressor, always operate compressor within rated
working pressure of the compressor. Never use a pressure switch with a higher cut-off pressure
than compressor’s rated working pressure.
WIRE GAUGE GUIDE 12-VOLT:
USER MANUAL
380C - 480C COMPRESSOR KIT
Amp Draw
Length of wire from battery to compressor
10
15
20
25
30
10
14
12
10
10
10
15
12
10
10
8
8
20
10
10
8
6
6
25
10
8
6
6
6
30
10
8
6
6
4
40
8
6
6
4
4
50
6
6
4
4
2
60
6
4
4
2
2