background image

OPERATING INSTRUCTIONS

Please  read  and  follow  the  operating  instructions 
carefully to assure that you will enjoy the convenience 
and best use out of your air compressor.   

IMPORTANT:  

1.

Always  operate  the  compressor  AT  OR  BELOW  THE 
MAXIMUM  PRESSURE  RATING  of  the  compressor.  
Refer to Specifications section of this manual.

2.

Always  OBSERVE  THE  MAXIMUM  DUTY  CYCLE  of  the 
air  compressor.    Refer  to  Specifications  section  of  this 
manual  for  details.  Operations  exceeding  maximum 
pressure ratings and or duty cycle will result in damage 
to air compressor.

3.

Your  air  compressor  is  equipped  with  an  AUTOMATIC 
THERMAL  OVERLOAD  PROTECTOR.    This  feature  is 
designed  to  protect  the  air  compressor  from  over-
heating  causing  permanent  damage  to  your  air 
compressor.  The  thermal  overload  protector  will 
automatically  cut  off  power  to  air  compressor  should 
internal operating temperature of the air compressor rise 
above safe levels during excessive use. 

4.

Should  at  any  time  during  use,  your  air  compressor 
automatically  shuts  off,  do  not  attempt  to  restart  air 
compressor.    Turn  ON/OFF  switch of  air compressor to 
the  OFF  position.  The  automatic  thermal  overload 
protector  will  automatically  reset  when  internal 
temperature  of  the  air  compressor  drops  below  safe 
level.  After allowing air compressor to cool off for about 
30  minutes,  you  can  safely  resume  use  of  the  air 
compressor by turning on the air compressor.

5.

Please  note  that  you  may  experience  a  slight  delay 
(about  ½  second)  of  the  compressor’s  motor  starting 
when  the  On/Off  Switch  is  turned  on  while  compressor 
is pressurized (when there is pressure in the line that the 
compressor is connected to).  This is a normal delayed 
reaction, not a Compressor ON/OFF switch malfunction.

6.

It  is  strongly  recommended  that  you  keep  the  vehicle’s 
engine  running  while  using  the  air  compressor  to 
prevent discharge of your vehicle’s battery. 

7.

ONLY  OPERATE  THE  AIR  COMPRESSOR  IN  WELL 
VENTILATED  AREAS.  Compressor  performance  is 
enhanced  when  operating  compressor  with  vehicle 
engine running.

Summary of Contents for 40043- 400P

Page 1: ...TABLE COMPRESSOR SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL IMPORTANT It is essential that you and any other operator of the product read and understand the contents of this manual before installing and using this product ...

Page 2: ...o not touch any part of this compressor with bare hands other than the ON OFF switch during and immediately after use Do not use this product near flames or explosive materials or where aerosol products are being used Do not operate this product where oxygen is being administered Do not pump anything other than atmospheric air Never use this product while sleepy or drowsy Do not use any tools or a...

Page 3: ...e levels during excessive use 4 Should at any time during use your air compressor automatically shuts off do not attempt to restart air compressor Turn ON OFF switch of air compressor to the OFF position The automatic thermal overload protector will automatically reset when internal temperature of the air compressor drops below safe level After allowing air compressor to cool off for about 30 minu...

Page 4: ...sture and Dust Resistant but NOT WATER OR DUST PROOF Never place compressor in soft sand while running the compressor Vibration from the compressor will cause the compressor to settle into soft sand resulting in compressor drawing in foreign particles Never expose compressor to water while running the compressor IMPORTANT Make sure compressor sits upright while operating compressor Avoid tugging a...

Page 5: ...ANDS FREE CONTINUOUS DEFLATION 1 Push the tire chuck with the lever in the upright position down over the tire valve stem and then push the lever down to the horizontal position to lock in place 2 Push Deflator Collar toward tire valve stem and turn Deflator Collar clockwise to engage lock 3 When desired pressure if reached turn Deflator Collar counterclockwise to disengage lock C INTERMITTENT DEF...

Page 6: ...essure buildup if tire chuck is not attached to tire valve stem while air compressor is in operation IMPORTANT Always use an Open Ended tire chuck such as the tire chuck equipped on the Inflator Deflator Coil Hose for tire inflation when using a compressor without an air tank CAUTION Never touch the air compressor or fittings connected to the air compressor other than the ON OFF switch with bare h...

Page 7: ... high 2 Compressor valves failed 1 Worn bearing on eccentric or motor shaft 2 Cylinder or piston ring is worn 1 Worn piston ring or inlet valve 1 Make sure compressor switch is ON 2 Disconnect compressor from power source replace fuse Refer to Specifications section for correct fuse 3 Let compressor cool off for about 30 minutes for thermal overload switch reset 1 Move compressor to well ventilate...

Page 8: ...t Motor Type Permanent Magnetic Max Intermittent Pressure 150 PSI Max Duty Cycle 33 15 on 30 off Min On Off 72ºF 100 PSI Continuous Use 72ºF 30 PSI Approx 40 Minutes Max Current Consumption 30 Amps Fuse 40 Amps Inline Pressure Gauge 160 PSI Auto Reset Thermal Protection Yes ...

Page 9: ...ginal date of purchase To receive warranty service or repair please contact VIAIR Corporation Returns should be made within one year of the date of purchase after a Return Goods Authorization RGA number has been assigned by VIAIR Corporation To obtain RGA fax a copy of your receipt to 949 585 0188 For complete warranty details please visit www viaircorp com warranty PLEASE NOTE THIS WARRANTY COVER...