background image

ESCAPADE HEAVY DUTY & CONSTANT DUTY COMPACT OBA SYSTEMS

USER MANUAL

OPERATING INSTRUCTIONS

 

1. IMPORTANT: Always operate the compressor at or below the MAXIMUM PRESSURE RATING of  

 

  the compressor. Please refer to Application & Specifications Sections of this manual for details.

2.  Always observe the MAXIMUM DUTY CYCLE of the air compressor. Refer to Compressor  

  Applications and Specifications Sections of this manual for details. Operation exceeding  

  maximum pressure ratings and/or duty cycle will result in damage to the air compressor. 

3.  Your air compressor is equipped with an AUTOMATIC THERMAL OVERLOAD PROTECTOR. 

 

  This feature is designed to protect the air compressor from overheating and causing permanent  

  damage to your air compressor. The thermal overload protector will automatically cut power to  

  your air compressor should the internal operating temperature of the air compressor rise above  

  safe levels during excessive use. 

4.  Should at any time during use, your air compressor automatically shuts off unexpectedly; do not  

  attempt to restart it. Turn off power and allow unit to cool for at least 30 minutes. This will allow  

  the Thermal Overload Protector to reset so you can safely resume use of the air compressor.

5.  To prevent discharge of your vehicle's battery, and enhance performance, keep the vehicle's  

  engine running while using the compressor. 

6.  Only operate compressor in well ventilated areas. 

NOTE:

 Your Escapade Heavy Duty/Constant Duty Compact OBA Systems are equipped with a 

sealed pressure switch. Due to manufacturing tolerances, a variance of +/- 5% is possible for turn 

on & off pressures. This is not a manufacturing defect, and will not affect the operation of air lockers, 

nor the ability of the OBA Kit to inflate tires.

MAINTENANCE & REPAIRS

1.  Periodically check all electrical and fittings connections. Clean and tighten as needed. 

2.  Periodically check all mounting screws. Tighten as needed.

3.  Replace air filter element periodically. Replacement frequency depends on operating frequency 

 

  and operating environment. For frequent use in dusty environment, you should replace air filter 

 

  element more oft.n. 

4.  Regularly clean dust and dirt from compressor cooling fins and/or motor housing.

5.  Your air compressor is equipped with a permanently lubricated, maintenance-free motor. Never try to 

 

  lubricate the compressor.

6.  All repairs should be performed by Manufacturer or Manufacturer's Authorized Service Agencies only. 

7.  For complete information regarding VIAIR

®  

Warranty, please visit: 

www.VIAIRcorp.com/warranty

 

 

CAUTION:

 

Never touch the air compressor or fittings connected to the air compressor, with bare hands during 

or immediately after use. The fittings connected may become very HOT during and after use. If 

necessary, wear heat resistant gloves to handle fittings and coil hose. 

Summary of Contents for 50001

Page 1: ... of this product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE 50001 Escapade Heavy Duty Compact OBA 50003 Escapade Constant Duty Compact OBA ADVENTURE SERIES SERIES USER MANUAL ...

Page 2: ...l protector becomes activated Wear safety glasses or goggles when operating this product Use only in well ventilated areas INSTALLATION Please read and follow the installation instructions carefully to avoid injury or damage to the compressor or your vehicle Each of our air compressors and parts have been carefully produced and packaged Before you begin installation please familiarize yourself wit...

Page 3: ...ystem will automatically turn on and fill the reservoir tank 9 When the cutoff pressure of the Escapade Heavy Duty Constant Duty Compact OBA has been reached the system will shut off automatically 10 Inspect all air line connections for leaks with soap and water solution If a leak is detected the connection may not be made properly Re do any connections that are leaking The use of thread locker is...

Page 4: ...keep the vehicle s engine running while using the compressor 6 Only operate compressor in well ventilated areas NOTE Your Escapade Heavy Duty Constant Duty Compact OBA Systems are equipped with a sealed pressure switch Due to manufacturing tolerances a variance of 5 is possible for turn on off pressures This is not a manufacturing defect and will not affect the operation of air lockers nor the abi...

Page 5: ...ction Yes Ingress Protection Rating IP67 ABOUT COMPRESSOR DUTY CYCLE Duty cycle refers to the amount of time a compressor can be operated in a given time period at 100 PSI and a standard ambient temperature of 72 F It is commonly expressed in percentage format Compressor on time on time off time Duty Cycle ONE HOUR DUTY CYCLE MINUTES ON 100 PSI 72 F MINUTES OFF 9 5 min On 55 min Off 10 6 min On 54...

Page 6: ... or other inflatable items 3 Checking Tire Pressure To check tire pressure release Inflation Trigger on Inflation Gun and allow the needle of the 0 160 PSI gauge to settle Tire pressure will be able to be read only when the inflation trigger is released WARNING Never operate the Inflation Gun at any pressure exceeding 160 PSI Use caution when attaching or removing air chuck from valve stems Always...

Page 7: ...itch 2 Replace safety valve Excessive moisture in discharge 1 Excessive water in air tank 2 High humidity 1 Drain tank tilt tank to drain Drain tank more frequently 2 Move compressor to area with less humidity or use air line filter Compressor will not run 1 No power or power switch in OFF position 2 Blown fuse 3 Motor overheats 4 Faulty pressure switch 1 Make sure compressor switch is ON 2 Discon...

Page 8: ...or complete warranty details please visit www viaircorp com warranty PLEASE NOTE THIS WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE This Manual is proprietary to VIAIR Corporation and no ownership rights are hereby transferred No part of the Manual shall be used reproduced translated converted adapted stored in a retrieval s...

Reviews: