2.2

 

Fibre Optic Cable & Connectors 

2.2.1

 

Connector and Cable Types 

All 

ViaLite

  Ethernet  Transceiver  modules  use  singlemode  (9µm/125µm)  cable  terminated  with  either 

FC/APC  or  E2000/APC  optical  connectors.    Cross-site  fibre  optic  cables  are  available  from  PPM  as 
either standard patch leads or heavy-duty multicore cables. 
 

Warning! 
FC/APC  and  E2000APC  are  standards  for  angle-polished  connectors  and  must  not  be  confused 
with  standard  FC/PC  and  E2000  connectors  respectively.    The  two  connector-types  are  not 
interchangeable  and  mating  one  with  the  other  will  damage  both  the  cable  and  the  module 
connectors. 
 

 

The specification of the FC/APC and E2000APC optical connector is critical to the performance 
of  the  complete  fibre  optic  link.  System  performance  can  only  be  guaranteed  with  fibre  optic 
cables  and  connectors  supplied  by  PPM.    FC/APC  connectors  must  be  “narrow  key  width”  (see 
technical specification). 

2.2.2

 

Connecting and Disconnecting 

Before  connecting  optical  fibres  to  the  module  or  to  each other, ensure that the mating connectors are 
clean (see below). 

2.2.2.1

 

FC/APC 

To connect FC/APC optical connectors, remove the dustcaps and align the white ceramic centre ferrule 
on the cable connector with the receptacle.  There is a lug on the side of the ferrule, which must match 
the gap in the receptacle shroud.  When they are aligned, gently push the plug home and finger tighten 
the knurled collet nut onto the threaded receptacle.  See Figure 1 below. 
 
To disconnect FC/APC connectors, unscrew the knurled collet on the plug and gently withdraw the plug.  
Replace the dustcaps on both the receptacle and the cable plug. 
 

Ethernet Optical 

Transceiver 

Summary of Contents for LSX-Ex-HB-2

Page 1: ...al Transceiver User Manual LSX Ex HB 2 CR2686 01 06 09 Pulse Power Measurement Ltd 65 Shrivenham Hundred Business Park Watchfield Swindon Wiltshire SN68TY UK Tel 44 0 1793 784389 Fax 44 0 1793 784391 Email sales ppm co uk www vialite co uk ...

Page 2: ...2 ...

Page 3: ...ype anti surge quick blow etc are used for replacement Optical Safety The ViaLite Ethernet Optical Transceiver modules contain laser diode sources operating from 1270nm to 1610nm These devices are rated at under IEC825 1 Safety Of Laser Products Part 1 First Edition 1993 as CLASS 1 radiation emitting devices When operating the equipment note the following Never look into the end of an optical fibr...

Page 4: ...Cable Connectors 7 2 2 1 Connector and Cable Types 7 2 2 2 Connecting and Disconnecting 7 2 2 3 Minimum Bend Radius 9 2 3 Using the Ethernet Optical Transceiver 10 2 3 1 Front Panel Indicators 10 3 PART NUMBERING 12 4 TRANSCEIVER SPECIFICATIONS 13 5 MAINTENANCE AND FAULT FINDING GUIDE 14 5 1 1 Troubleshooting Chart 14 6 PRODUCT WARRANTY 14 ...

Page 5: ...nits with part numbers starting LSX E2 100Mb s only and LSX E4 10 100 1000Mb s auto negotiating Optical fibre interconnects with part numbers starting F6 or F7 The D Type to RJ45 converter cable 73636 The Ethernet optical links comprise two Transceivers linked by two Fibre Optic Cables The Fibre Optic Cable is single mode fibre type depending on span length and uses FC APC type or E2000 APC connec...

Page 6: ...nnections are on the rear panel of the Transceiver see below Connector A is a DIN 41612 backplane connector providing power and Ethernet connectivity to the module Connectors B are FC APC or E2000 APC receptacles These are the optical connections for linking the Transceivers together Connector Type A Connector Type B Connections on the rear of the Transceiver A short RJ45 to D connector adapter ca...

Page 7: ...mance of the complete fibre optic link System performance can only be guaranteed with fibre optic cables and connectors supplied by PPM FC APC connectors must be narrow key width see technical specification 2 2 2 Connecting and Disconnecting Before connecting optical fibres to the module or to each other ensure that the mating connectors are clean see below 2 2 2 1 FC APC To connect FC APC optical...

Page 8: ...aded and should spring back to protect the ferrule Care and Cleaning The optical connectors should be cleaned before each and every use even where they have been protected with dust caps Cleaning items required Lint free fibre cleaning tissues and or cleaning sticks normal cosmetic tissues produce dust and are not acceptable Reagent grade Iso Propyl Alcohol Air duster or FILTERED compressed air li...

Page 9: ...or an instrument unless you are convinced that there is no optical radiation being emitted by the fibre Remove all power sources to all modules and completely disconnect the optical fibres 2 2 3 Minimum Bend Radius Because the optical fibre is made of glass it is important not to subject it to excessive stress For this reason each type of cable has a minimum bend radius MBR specification beyond wh...

Page 10: ...re interfaces are incompatible To establish a successful working link two modules with the same speed specifications must be used 2 3 1 Front Panel Indicators The Transceiver has a number of front panel LEDs for indication of essential status information of the module The following table shows the operation of the front panel LEDs 100Mb s Ethernet Optical Transceiver LED Function Pwr Illuminates t...

Page 11: ... Steady ON when port is running at 1000Mb s default OFF when port is running at 10 100Mb s Fibre Port RX ACT Steady ON for LINK LK with no traffic Blinking for activity LINK Steady ON when port is running at 1000Mb s default OFF when port is running at 10 100Mb s Copper Port RX ACT Steady ON for LINK LK with no traffic Blinking for activity ...

Page 12: ...tching X Transceiver Note the standard module has 1310nm laser but 1550nm and CWDM lasers are also available for long haul applications please contact PPM for part numbers Important Note Ethernet Optical Transceiver Modules with part numbers beginning LSX E2 and LSX E4 are not compatible and cannot be used for form a working fibre optic link ...

Page 13: ...Power Connector User accessible 15 way D type Female via 19 Rack Shelf backplane User accessible 15 way D type Female via 19 Rack Shelf backplane Module Operating Voltage and Power 4W at 12V 0 5V Typical 4W at 12V 0 5V Typical Operating Conditions Operating Temperature 0 C to 50 C 0 C to 50 C Storage Temperature 40 C to 80 C 40 C to 80 C Ambient Relative Humidity 10 to 95 Non Condensing 10 to 95 N...

Page 14: ...uring installation 6 Product Warranty PPM guarantees its products and will maintain them for a period of three years from the date of shipment and at no cost to the customer Extended warranty options are available at the time of purchase Please note that the customer is responsible for shipping costs to return the unit to PPM PPM or its agents and distributors will maintain its products in full wo...

Page 15: ...type pin No Description 1 Orange white wire from RJ45 connector 2 Green white wire from RJ45 connector 3 Blue white wire from RJ45 connector 4 Brown white wire from RJ45 connector 5 6 7 8 9 Orange wire from RJ45 connector 10 Green wire from RJ45 connector 11 Blue wire from RJ45 connector 12 Brown wire from RJ45 connector 13 14 15 ...

Page 16: ...MENT LTD NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM WITHOUT PRIOR WRITTEN PERMISSION PPM LTD 65 SHRIVENHAM HUNDRED BUSINESS PARK SWINDON SN6 8TY UK TEL 44 1793 784389 FAX 44 1793 784391 EMAIL INFO PPM CO UK WEBSITE WWW PPM CO UK ...

Reviews: