Operation, Operating Procedures and Test Configurations
Operating Procedures
1-2-4
ATC-5000NG ATC/DME Test Set Operation Manual
Rev. L0
Page 2
Subject to Export Control. See Cover Page for details.
February 2020
Table 1.2.4 - 1
Transponder Generator Assignments - Single Test Mode
1
Default Antenna
Port
Top
Top
Bottom
Bottom
Top
Top
Interrogation Type
Generator
A
Generator
B
Generator
C
Generator
D
Generator
E
Generator
F
All SIF Modes (Cal
& Var)
P1 and P3
P2 and P4
P1 and P3
P2 and P4
-
-
P1 - P2
P1
P2
-
-
-
-
P1
P1
-
-
-
-
-
Alternate Mode A
& Mode C
P1 and P3
P2
P1 and P3
P2
DME
P1
P2
-
-
-
-
Mode S (All Pulses
Cal & No P5)
-
P1, P2
and P6
-
P1, P2
and P6
-
-
Mode S (P2 Var
Only)
P2 (Var)
P1 and P6
(Cal)
P2 (Var)
P1 and P6
(Cal)
-
-
Mode S (P6 Var
Only)
P1 and P2
(Cal)
P6 (Var)
P1 and P2
(Cal)
P6 (Var)
-
-
Mode S (P5 Cal &
Var)
P5 (Cal &
Var)
P1, P2
and P6
(Cal)
P5 (Cal &
Var)
P1, P2
and P6
(Cal)
-
-
Interference
Pulses (Cal & Var)
-
-
-
-
P1, P2
-
1
For Mode S Interrogations only P2 or P6 can be selected for variable pulse amplitude, not
both. If P2 or P6 is selected as variable P5 is disabled.