Operation, Remote Operation
Scenario Commands
Rev. L0
ATC-5000NG ATC/DME Test Set Operation Manual
1-2-5
February 2020
Subject to Export Control. See Cover Page for details.
Page 55
5.7.2.9.2.B
STATIC IDENTIFICATION SCHEDULE
5.7.2.9.2.B.1
INTERVAL ENABLE
5.7.2.10
MODE A CODE
5.7.2.11
MODE
5.7.2.12
MODE-S ALL CALL REPLY (DF=11) MESSAGE
DF11 squitter is transmitted by the ATC-5000NG at a rate of 1.0 seconds.
Dynamic intruders (targets) allow definition of multiple time intervals where the DF11 squitter can be
enabled or disabled.
Static intruders (targets) allow the user to enable or disable the DF11 squitter for the entire scenario.
5.7.2.12.1
MODE-S ALL CALL REPLY (DF=11) MESSAGE SCHEDULE
5.7.2.12.1.A
DYNAMIC DF=11 SCHEDULE
5.7.2.12.1.A.1
INTERVAL ENABLE
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC:}<intruder no>{:SIDENT}{:ENA
|:ENABLE}SP{ON | OFF}CR
Description:
This command enables or disables the identification squitter message of the specified intruder.
Default:
On
Example:
:ATC:SCE:STAT:2:SIDENT:ENA ON\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}<intruder
no>{:ACODE}SP<numeric>CR
Description:
This command sets the Mode A code.
Numeric:
0 to 7777 (octal ASCII)
Default:
0000
Example:
:ATC:SCE:STAT:1:ACODE 1234\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:STAT: |:STATIC: |:DYN: |:DYNAMIC:}<intruder
no>{:MOD |:MODE}SP{ TIS-B | EXTENDED | ADS-R | UAT}CR
Description:
This command sets the selected intruder to a specific intruder type. The intruder types are TIS-B,
Mode S Extended, ADS-R or UAT. When the intruder type is set to ADS-R, the Control Field (CF)
is set with the Value6 automatically. To define the UAT intruder parameters, refer to
para 1-
2-5.UAT ADS-B DEFINITION PARAMETERS
)
.
Default:
EXTENDED
Example:
:ATC:SCE:STAT:1:MOD EXTENDED\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:DYN: |:DYNAMIC:}<intruder no>{:SDF11}{:INT:
|:INTERVAL:}<interval number>{:ENA |:ENABLE}SP{ON | OFF}CR
Description:
This command enables or disables the DF11 squitter message of the specified intruder.
Default:
On
Example:
:ATC:SCE:DYN:2:SDF11:INT:3:ENA ON\r
Summary of Contents for 138156