Operation, Remote Operation
Scenario Commands
1-2-5
ATC-5000NG ATC/DME Test Set Operation Manual
Rev. L0
Page 72
Subject to Export Control. See Cover Page for details.
February 2020
5.7.2.19.2
TARGET STATE AND STATUS MESSAGE SCHEDULE
Target State and Status squitter is transmitted by the ATC-5000NG at a rate of 1.0 seconds.
Dynamic intruders (targets) allow definition of multiple time intervals where the Target State and Status
squitter can be enabled or disabled.
Static intruders (targets) allow the user to enable or disable the Target State and Status squitter for the
entire scenario.
5.7.2.19.2.A
DYNAMIC TARGET STATE AND STATUS SCHEDULE
5.7.2.19.2.A.1
INTERVAL ENABLE
5.7.2.19.2.A.2
INTERVAL QUANTITY
5.7.2.19.2.A.3
INTERVAL START TIME
5.7.2.19.2.A.4
INTERVAL STOP TIME
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:DYN: |:DYNAMIC:}<intruder no>{:STARGET}{:INT:
|:INTERVAL:}<interval number>{:ENA |:ENABLE}SP{ON | OFF}CR
Description:
This command enables or disables the target state and status squitter message of the specified
intruder.
Default:
On
Example:
:ATC:SCE:DYN:1:STARGET:INT:1:ENA ON\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:DYN: |:DYNAMIC:}<intruder no>{:STARGET}{:NINT
|:NINTERVALS}SP<numeric>CR
Description:
This command sets the number of target state and status squitter message intervals for the
selected intruder. The spaces not defined between intervals are considered off; therefore,
only
the user
can define
the intervals where
the message
is
transmitted
.
Numeric:
0 to 255 (decimal ASCII)
Example:
:ATC:SCE:DYN:1:STARGET:NINT 3\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:DYN: |:DYNAMIC:}<intruder no>{:STARGET}{:INT:
|:INTERVAL:}<interval number>{:BEGIN}SP<numeric>CR
Description:
This command sets the start time for the selected target state and status squitter message
interval for the selected intruder. The spaces not defined between intervals are considered off;
therefore,
only
the user
can define
the intervals where
the message
is
transmitted
.
Numeric:
0 to 6550 seconds (decimal ASCII). Resolution is 0.1 seconds.
Example:
:ATC:SCE:DYN:1:STARGET:INT:2:BEGIN 40\r
Command Syntax:
{:ATC |:ATC5000NG}{:SCE |:SCENARIO}{:DYN: |:DYNAMIC:}<intruder no>{:STARGET}{:INT:
|:INTERVAL:}<interval number>{:END}SP<numeric>CR
Description:
This command sets the stop time for the selected target state and status squitter message
interval for the selected intruder. The spaces not defined between intervals are considered off;
therefore,
only
the user
can define
the intervals where
the message
is
transmitted
.
Numeric:
0 to 6550 seconds (decimal ASCII). Resolution is 0.1 seconds.
Example:
:ATC:SCE:DYN:1:STARGET:INT:2:END 101\r