Operation, Remote Operation
Unit Commands
Rev. L0
ATC-5000NG ATC/DME Test Set Operation Manual
1-2-5
February 2020
Subject to Export Control. See Cover Page for details.
Page 129
5.10.6
RESET
5.10.7
SERIAL NUMBER REQUEST
5.10.8
SOFTWARE VERSION REQUEST
5.10.9
UNIT NAME REQUEST
Command Syntax:
{:ATC |:ATC5000NG}{:RESET}CR
Description:
This command executes a global reset to the Unit. A 10 second delay is recommended to allow
this command to complete before reading the reply. This global reset includes the following
tasks:
Stop any execution.
Reset RTCA/DO-260 Test.
Reset Transponder Test.
Reset Own Aircraft Position. Set the Own Aircraft Latitude, Longitude, Heading and Altitude to
zero. Set the Own Aircraft Mode S Address to 4.
Reset Scenario.
Set the ATC-5000NG to the factory default settings.
Return Value:
A”*” is returned if the factory settings are able to complete successfully or “?” if a failure occurs.
Example:
:ATC:RESET\r
Return:
*
Command Syntax:
{:ATC |:ATC5000NG}{:SN?}CR
Description:
This command returns the serial number of the Unit.
Return Value:
ASCII value
Example:
:ATC:SN?\r
Return:
1000000003
Command Syntax:
{:ATC |:ATC5000NG}{:SW?}CR
Description:
This command returns the software version of the Unit.
Return Value:
ASCII value
Example:
:ATC:SW?\r
Return:
26
Command Syntax:
{:ATC |:ATC5000NG}{:NAME?}CR
Description:
This command returns the Unit name.
Return Value:
ASCII value
Example:
:ATC:NAME?\r
Return:
ATCSN1000000003