Operation, Remote Operation
DME Commands
1-2-5
ATC-5000NG ATC/DME Test Set Operation Manual
Rev. L0
Page 134
Subject to Export Control. See Cover Page for details.
February 2020
5.11.19
PRF?
5.11.20
PULSE
5.11.21
RANGE
5.11.22
RANGE MODE
5.11.23
RESET
5.11.24
SAVE TEST
Command Syntax:
{:ATC |:ATC5000NG}{:DME:PRF?}CR
Description:
This command returns the UUT transmission rate.
Return Value:
Decimal value in ASCII. (Number of transmissions in the last second.)
Example:
:ATC:DME:PRF?\r
Return:
101
Command Syntax:
{:ATC |:ATC5000NG}{:DME:PULSE} SP{P1 | P2}CR
Description:
This command sets which pulse to measure.
Default Value:
P1
Example:
:ATC:DME:PULSE P1\r
Query:
:ATC:DME:PULSE?\r
Return:
P1
Command Syntax:
{:ATC |:ATC5000NG}{:DME:RANGE} SP<numeric>CR
Description:
This command sets the DME range.
Numeric
0 to 400 nmi (decimal ASCII)
Default Value:
0 nmi
Example:
:ATC:DME:RANGE 100\r
Query:
:ATC:DME:RANGE?\r
Return:
100.
Command Syntax:
{:ATC |:ATC5000NG}{:DME:RANGE}{:OFF | OFFSET} SP{-1 | NORMAL}CR
Description:
This command selects the normal range simulation or
‐
1 nmi range simulation.
Default Value:
Normal
Example:
:ATC:DME:RANGE:OFF -1\r
Query:
:ATC:DME:RANGE:OFF?\r
Return:
-1
Command Syntax:
{:ATC |:ATC5000NG}{:DME}{:RES |:RESET}CR
Description:
This command resets the DME Test.
Example:
:ATC:DME:RES\r
Command Syntax:
{:ATC |:ATC5000NG}{:DME}{:SAVE}SP<filename>CR
Description:
This command saves the current DME Test into the internal storage area with the specified
filename.
Example:
:ATC:DME:SAVE test1\r