Operation, Remote Operation
DME Commands
Rev. L0
ATC-5000NG ATC/DME Test Set Operation Manual
1-2-5
February 2020
Subject to Export Control. See Cover Page for details.
Page 135
5.11.25
SQUITTER
5.11.26
START
5.11.27
STOP
5.11.28
SUPPRESSION
5.11.29
SUPPRESSION PERCENTAGE
Command Syntax:
{:ATC |:ATC5000NG}{:DME}{:SQUIT |:SQUITTER} SP<numeric>CR
Description:
This command sets the DME squitter rate.
Numeric
0 to 8000 transmissions per second (decimal ASCII)
Default Value:
2700
Example:
:ATC:DME:SQUIT 500\r
Query:
:ATC:DME:SQUIT?\r
Return:
500
Command Syntax:
{:ATC |:ATC5000NG}{:DME:START} CR
Description:
This command starts the DME transmissions of squitters and replies.
Example:
:ATC:DME:START\r
Command Syntax:
{:ATC |:ATC5000NG}{:DME:STOP}CR
Description:
This command stops the DME transmissions of squitters and replies.
Example:
:ATC:DME:STOP\r
Command Syntax:
{:ATC |:ATC5000NG}{:DME:}{SUPP | SUPPRESSION} SP{ON | OFF}CR
Description:
This command enables or disables the suppression output.
Default Value:
Off
Example:
:ATC:DME:SUPP ON\r
Query:
:ATC:DME:SUPP?\r
Retrun:
ON
Command Syntax:
{:ATC |:ATC5000NG}{:DME:}{SUPP | SUPPRESSION}{:PERCENT |:PERCENTAGE}
SP<numeric>CR
Description:
This command sets the percentage of suppression when suppression is activated.
Numeric
0 to 100 (decimal ASCII)
Default Value:
100
Example:
:ATC:DME:SUPP:PERCENT 90\r
Query:
:ATC:DME:SUPP:PERCENT?\r
Return:
90
Summary of Contents for 138156
Page 3: ......