Operation, Menus and Screens
System Menu
1-2-3
ATC-5000NG ATC/DME Test Set Operation Manual
Rev. L0
Page 112
Subject to Export Control. See Cover Page for details.
February 2020
The ATC-5000NG sets the gateway address to the same IP Address and internally, sets the DSP IP
address and communicates the address to the DSP module when the user presses the Set Softkey. The
application software communicates the new address to the DSP, resets the connection and reboots the
DSP. This process takes a few minutes. At the end of the process the application software re-establishes
communications with the DSP using the new IP Address. On all future reboots the current IP address is
used.
Restore Factory Setup
To return to the factory setup, enter the same screen and press the Factory Setup Softkey. The
application software starts the change process again with the IP address set to 192.168.0.1.
3.8.2.2
Change Settings Menu - Use the Following IP Address
Figure 1.2.3 - 78
Network Connections, Change Settings Menu - Manual IP Address