4.2 Description of Functions
Item Set
Value
Description
0
Disable
Bar graph display
1. b.G.
☆
1
Enable
☆
0
Disable
Limit function
2.SEL
1
Enable
☆
1
Always judge (judges even when the balance is
unstable)
Judgement
condition
21.Co.
2
Judge only when the balance is stable (does not
judge if the balance is unstable)
0
Ranges 5 graduation is judged (5
graduation or below, including negative ranges, are
not judged.)
Judgement
range
22.Li
☆
1
The entire range is judged (the entire range,
including the negative, is judged).
1
One-point setup (judges between OK and LO)
Displayed only when limit
function is activated
Number of
points for
judgement
23.Pi
☆
2
Upper-limit and lower-limit values are set up (judges
among HI, OK and LO).
0
Disable (balance operates
continuously)
Auto power-off
4. A.P.
☆
1
Enable (balance powers off
in approximately three
minutes)
This function is
available only when
the balance is
battery-operated.
0
Measurement by consecutive weighings.
1
2
☆
3
4
Response speed
5. rE.
5
Fast
↓
Slow
☆
6 0
Disable input/output
☆
1
Six-digit numeric format
Interface
7. I.F.
2
Seven-digit numeric format
☆
1 01 [
g
]
☆
2 14 [ ] (ct)
15 [ ] (oz)
16 [ ] (lb)
17 [ ] (ozt)
18
[ ] (dwt)
19
Ú
1
[
Lower right
] (grain)
☆
3 20 [Pcs]
1F [ % ]
Setup of units of
measurement to be
displayed
Register selected
measuring units with
Function key.
81.S.u.
|
85.S.u.
☆
4,5 00 Unit not set
Items mrked
☆
are the default factory settings.
☆
1
~☆
5: default factory settings [81.S.u.]
~
[85.S.u.]
☆
6
: AJ-NTDB Type only
※
1 For
220g
~
6200g Capacity model