IECEx CERTIFICATE
Certificate No.: IECEx KEM 08.0016
Type of Protection: ia
Marking: Ex ia II B T4
STANDARS:
IEC 60079-0:2004 Edition: 4.0
IEC 60079-11:2006 Edition: 5
Test Report: NL/KEM/ExTR08.0012/00
EQUIPMENT:
Temperature Range: +5
°
C to +35
°
C
POWER SUPPLY:
GZ II-B, EZ II-B and EZ-B Series:
1.5 V Manganese dry cell batteries National/Panasonic
Type R14P (NR). (6 non-rechargeable)
GZ II, EZ II and EZ Series:
Maximum values Ui = 43 V; Ii = 170 mA; Pi = 0.931 W; Ci = 7.1 nF; Li = 0.75 mH.
The insulation between an intrinsically safe circuit and the frame of the (electrical) apparatus is not
guaranteed. Avoid excess voltage.
EC-TYPE EXAMINATION CERTIFICATE
Certificate No.:
KEMA 08ATEX0054
Marking:
STANDARS: EN
60079-0:2006
EN 60079-11:2007
Test Report: KEMA No. 211076300
EQUIPMENT:
Temperature Range: +5
°
C to +35
°
C
POWER SUPPLY:
GZ II-B, EZ II-B and EZ-B Series:
1.5 V Manganese dry cell batteries National/Panasonic
Type R14P (NR). (6 non-rechargeable)
GZ II, EZ II and EZ Series:
Maximum values Ui = 43 V; Ii = 170 mA; Pi = 0.931 W; Ci = 7.1 nF; Li = 0.75 mH.
The insulation between an intrinsically safe circuit and the frame of the (electrical) apparatus is
not guaranteed. Avoid excess voltage.
Ⅱ 2 G
Ex ia ⅡB T4