X-IA Input Pattern
Select an X-IA input pattern and define which alarms will be enabled as discussed in the next section. Use
the Tab key to move the cursor from the X-IA Input Pattern setting to the group of input numbers.
Note: Upon power-up,
Powerplus will default
pattern A. When if is
for
nexf pattern
begin,
Powerplus will follow
system programming.
Settings:
Keys:
Numeric keypad’s + (plus) key or (minus) key
Default:
A
X-IA Alarm Inputs
Enable the X-IA alarms that will be part of the pattern shown in X-IA Input Pattern at the top of the screen.
The Tab key is used to move back up to the X-IA Input Pattern setting so that the next pattern may be
defined.
Settings:
Keys:
Default:
Enabled
Disabled
Numeric keypad’s + (plus) key or (minus) key
Shift and numeric keypad’s + (plus) or (minus) key to set all alarms past
Enabled
Set Momentary Inputs
A momentary alarm remains active only as long as the alarm switch contacts are in the position which
defines an alarm. For example, some alarms are activated when the contacts close (normally open) and
others when the contacts open (normally closed). If a normally-closed momentary alarm is connected to a
door, the alarm is active only while the door is open. Latching alarms remain in their current state, for
example, a latching normally-closed door alarm will activate when the door is opened and remain active until
the alarm is acknowledged. The default state of X-IA alarms is latching. X-IA alarms must be set as
momentary or latching using Powerplus software. Note that all receiver alarms are latching.
Patterns of X-IA alarms may be specified as momentary or latching. Three patterns are available. The use of
patterns allows X-IA alarms to operate as a group. For example, an Alarm Type event using pattern A could
be scheduled for daylight hours and pattern B could be reserved for night. Pattern A might set all X-IA alarms
to act as momentary in this example, while pattern B sets all X-IA alarms to act as latching. The X-IA alarm
numbers on this screen will be set as momentary or latching in the pattern identified at the top of the screen.
Note that both momentary/latching patterns and X-IA input patterns (discussed in the previous section) use
the settings A, B, and C. However, the A, B, and C momentary/latching patterns are completely independent
of the A, B, or C X-IA input patterns. Each alarm input must be specified as either latching or momentary in
the menu shown below (all alarms are latching by default and must be deliberately selected as momentary).
Also, all alarms must be individually enabled as discussed in
Enable A/arm
on page 42, independent
of the momentary/latching assignment. Selecting an alarm as momentary does not enable it.
X897 Rev 1196 Nova Powerplus
Alarm Actions
l
43
Summary of Contents for NOVA Powerplus VP3466
Page 17: ...This page intentionally left blank 6 l Preliminary Operations X897 Rev 1196 Nova Powerplus ...
Page 91: ...This page intentionally left blank 80 l Install Defaults X897 Rev 1196 Nova Powerplus ...
Page 95: ...This page intentionally lef t blank 84 l Error Messages X897 Rev 1196 Nova Powerplus ...
Page 97: ...This page in ten tionally left blank 66 l Shipping Instructions X897 Rev 1196 Nova Powerplus ...