Creating a Configuration
|
3-55
Pilot Plus
XX200-00
Field
Description
Priority Level
Use this field to assign a priority level from 0 – 64 to
the host computer. The highest priority is 0.
Seize Enable
Selecting Enabled will enable the host port to seize
control of cameras from keypads with a lower
priority.
Auto Manual
The Auto Manual setting specifies whether the seize
will occur automatically or must be initiated by a
special command.
Description
Use this field to enter a description for the host
computer. Maximum of 40 characters.
All selections are made using the Options Wizard. To change a field’s value,
proceed as follows:
1. Select the field that you wish to modify using the Available Field
selection box. You can scroll through all available options.
2. Upon selection, the title below Available Field will change to the
parameter selected and the appropriate values will display in the
selection box.
3. Select All for all, Selected Only for an item that is highlighted in the
list or From to specify a range.
4. Click Update to implement the changes.
Note:
The Settings box contains two buttons: Apply and Restore. Clicking
Apply will make the changes permanent. Clicking Restore will cancel the
changes that you have made and revert back to the original values. Once
you click Apply, you cannot restore the original values.