Quick Guide

Frequently Asked Questions

When power is applied to my Surveyor2000, it toggles between the diagnostic screen and the status 
screen in an endless loop.  What is the problem?

This symptom is usually caused by the dome being underpowered. Refer to the electrical portion of the Technical Information 
section in the Surveyor2000 Installation & Operation Manual for the table specifying maximum operating distances with various 
wire gauges.

How far can I place the Surveyor2000 from the power supply?

The dome must receive 22 to 34 VAC. Refer to the electrical portion of the Technical Information section in Surveyor2000 
Installation & Operation Manual for the table specifying maximum operating distances with various wire gauges.

Everything is wired and programmed but I do not have control of my Surveyor2000. What is the problem?

Thoroughly check all wiring to the Surveyor2000 including polarity (+ and –) and cross connection (Cin and Ro). Verify DIP switch 
settings for address and communications mode. 

The control of my Surveyor2000 is intermittent. What is wrong?

Check the data connections on the Surveyor2000 and on any other units linked to it through the Ro and Cin connections.

What address should I use for my Surveyor2000?

Use the number of the physical connection of the Surveyor2000 to the control system or matrix switcher. Define this number to the 
Surveyor2000 using switch S1 as discussed in the Surveyor2000 Installation & Operation Manual. Use this number when 
selecting the Surveyor2000's camera with a control device.

How do I get the Surveyor2000 to autopan continuously (360 degrees)?

Program the pan left and right stops (presets 98 and 99) to the same position. Refer to the Surveyor2000 Programming manual for 
setting stops.

What is the advantage of running duplex data as opposed to simplex?

Duplex configuration allows the Surveyor2000 to be supervised by the CPU. In the event of a failure, a failed message will be 
annunciated on the control device. Duplex also enables indication of autopan, autoiris, auxiliary and preset functions. Simplex 
configuration does not offer these features.

Fax: 631-951-CCTV (2288)  •  U.K.:  44/(0) 1489/566322

5

Summary of Contents for Surveyor2000

Page 1: ...ms Camera Dome System ZOOM IN IRIS OPEN ZOOM OUT FOCUS FAR FOCUS NEAR IRIS CLOSE RUN PGM Quick Guide This Vicon Quick Guide is intended to get you up and running quickly See the complete manuals for in depth information on the Surveyor2000 1 ...

Page 2: ...s A sector is a specific portion of the 360 viewing area Pan the selected camera to left end of sector 1 Enter preset 96 This defines the left end of sector 1 Pan to the right end of sector 1 Pan to the right end of sector 2 Press the autopan key This defines the right end of sector 1 the left end of sector 2 and displays the title of sector 2 Press the autopan key This defines the right end of se...

Page 3: ...rol device s joystick or the autopan key to make a menu selection Use the autoiris button to exit the menu Select a monitor Select a camera Enter preset 94 Pan Tilt Controller Adjust max pan tilt speeds and enable disable the zoom scalable pan tilt feature Camera Controller Adjust autoiris autofocus shutter speed and V phase Alarm Handling Enable alarms and reports define alarm status acknowledgem...

Page 4: ...mera Enter preset 88 or 89 Enter auxiliary number 1 Storing an Autotour Select a monitor Move camera to desired starting position Pan tilt and zoom to each step in the autotour Refer to the manual for details Enter auxiliary number 1 Press the autopan key to save autotour Deflect joystick up down to move to extra settings using right left to define NO ACTION Nothing happens PRESET Recalls preset A...

Page 5: ...ddress and communications mode The control of my Surveyor2000 is intermittent What is wrong Check the data connections on the Surveyor2000 and on any other units linked to it through the Ro and Cin connections What address should I use for my Surveyor2000 Use the number of the physical connection of the Surveyor2000 to the control system or matrix switcher Define this number to the Surveyor2000 us...

Reviews: